Using chestbelt heart rate sensor, Setting the date – CatEye MODEL EC-1600 User Manual
Page 28
48
Using chestbelt heart rate sensor
Wireless chestbelt sensor picks up your heart rate
In place of the earlobe pulse sensor, the EC-1600 can also receive
your pulse signal transmitted from a particular type of wireless
chestbelt sensor. The "Wireless Pulse Sensor Kit" (an optional item)
is recommended for the customers who may feel inconvenience in
picking up the pulse rate from the earlobe.
Function of wireless chestbelt sensor
The wireless chestbelt sensor is a simplified and compact electrocar-
diograph as widely used in hospitals on the same principle. At hospi-
tals, electrodes are attached to several parts of the body, and a cardio-
gram is determined on the basis of potential differences among those
electrodes. The chestbelt sensor picks up the heart rate more simply
through potential difference between two electrodes built-in there
and in contact with the body.
The pulse data are transmitted to the control unit by radio wave, thus
eliminating inconveniences of handling the sensor cable and offering
concentrated intense training.
The "Wireless Heart Rate Sensor Kit" consists of a chestbelt sensor
unit (transmitter) and a receiving circuitry to be mounted inside of the
control unit.
Attaching the chestbelt sensor
The chestbelt sensor should be put around your chest with two elec-
trodes in contact with your body at the center.
For further information, please refer to the Manual enclosed in the
"Wireless Heart Rate Sensor Kit" (an optional item).
Chestbelt heart rate sensor adapted in
position
Direct contact to lower chest skin is ideal in use.
49
Displaying the Date
• W h i l e h o l d i n g d o w n
the
MODE
button, hit the RE-
SET button once, and the date
and time are displayed. (as displayed in the lower column)
Setting the Date
• By each press of the
MODE
button, different numerics will blink in
EC-1600
CADENCE
PEDAL
TORQUE
PROGRAM
NAME
TLD 1. 15 sec. work 45 sec. relief
Dash (Sprint Power) Training
TLD 2. 30 sec. work 60 sec. relief
Speed (Anaerobic Power) Training
TLD 3. 60 sec. work 30 sec. relief
Stamina (Aerobic Power) Training
Intensity of program is adjusted
according to PRF Number.
PRF 1 is least intense.
PRF 8 is most intense.
PRF 9. Design a profile as desired.
TLD.4. Make a training pattern as desired.
TIME
Hill Profile Preference
Interval Training Preference
ADV
RESET
10
1
10
1
MODE
the sequence of minute-
hour-date-month-year.
• Set the date and time by pressing the
buttons to increase
or decrease the blinking numeric.
• Once the minute is set, the clock starts working. So set at the actual
minutes without considering the time for setting other data.
Finishing the Setting
Setting the date
TIME
hour
year
month
date
minute
• When the setting is over, press
the
ADV
button. The LCD returns to the initial display (screen to
select a program).
• The date is printed out at the beginning of a printer printout.