beautypg.com

Aerobic power measurement (2), Physical fitness level (pfl), Test protocol – CatEye MODEL EC-1600 User Manual

Page 18

background image

28

(ml/kg min)

60

54

48

42

36

30

24

18

12

6

0

(Age) 20s 30s 40s 50s 60s

(ml/kg min)

60

54

48

42

36

30

24

18

12

6

0

(Age) 20s 30s 40s 50s 60s

Aerobic power measurement (2)

Physical Fitness Level (PFL)

• There are five physical fitness levels: 1 ~ 5. These levels are relative

evaluations that compare your maximum oxygen uptake (MOU), esti-
mated by the aerobic power measurement program, with the values of
other people of the same age and sex (Physical Fitness Level Test Table).

• Ergociser™ EC-1600 stores the following physical fitness level test table,

which can be selected by the selector switch on the back panel of the con-
trol unit. (See page 9)

[American Males]

[American Females]

• In the Ergociser™ EC-1600 "Aerobic power measurement" program the

weight of the pedals are changed at 3 levels, and the pulse rate at the end
point of each level is measured. Based on the result, the relationship be-
tween the work rate (wattage) and the pulse rate is analyzed by linear
regression. Extend the regression line until reaching the maximum heart
rate (=204–0.69 x age) which is estimated by age. The work rate (wattage)
of this point becomes the maximum physical work capacity.

• PWC max. safely estimates how much exercise is possible at the limit of

physical work capacity, that is, at maximum heart rate without perform-
ing actual exercise.

Maximum Physical Work Capacity (PWC max.)

Maximum Oxygen Uptake (MOU)

• MOU is widely used as an index for total physical endurance. MOU indicates the

amount of oxygen one can intake at the limit of their physical work capacity. In
the Ergociser™ EC-1600, MOU is calculated based on the maximum physical
work capacity (PWC max.) explained below, assuming that

1 litre of oxygen corresponds to 5.0 Kcal, and
the human body efficiency rate for a bicycle exercise is 23%

25 50 75 100 125 150 (watt)

180

140

120

80

(bpm)

Maximum Physical Work Capacity

Work Rate

Maximum Heart Rate

Heart Rate

Measurement

Estimate

Physical Fitness Level Test
Table by Maximum Oxygen
Uptake (MOU)

5: Excellent
4: Good
3: Average
2: Fair
1: Poor

MOU

MOU

29

1.5 kg

1.8 kg

2.2 kg

2.2 kg

2.6 kg

3.0 kg

3.0 kg

3.3 kg

3.5 kg

1.2 kg

1.8 kg

2.5 kg

1.0 kg

1.1 kg

1.4 kg

1.5 kg

1.8 kg

1.8 kg

2.5 kg

0.8 kg

1.0 kg

1.5 kg

0.5 kg

Pulse

135

120

Pulse<135

Pulse<120

Pulse

135

120

Pulse<135

Pulse<120

Pulse

135

120

Pulse<135

Pulse<120

Pulse

110

90

Pulse<110

Pulse<90

Pulse

123

Pulse<123

Pulse

123

Pulse<123

Pulse

123

Pulse<123

Pulse

115

Pulse<95

95

Pulse<115

Test Protocol

• In the "Aerobic power measurement" program of the EC-1600, the

workload (pedal resistance: torque) for the subsequent stage is deter-
mined depending on your pulse rate at the previous stage. The workload
(pedal resistance: torque) will be increased along one of the routes illus-
trated below, depending on your pulse rate ™during the program.

• The pulse rates specified below represent the protocol for a person of 20

years. For the people over 20, the borderline of pulse rate will be adjusted
by the age adjustment coefficient (K), which is obtained by the following
formula:

204–0.69 x Age

204–0.69 x 20

• For people over 60 years, the coefficient (K) is calculated as 60.

K =

Remark:

The load change for males over 50 years of age is the same as

for females.
When the age is less than 20, the load changes as if the age were 20.

Male