beautypg.com

Carrier AQUAZONE 50PCH User Manual

Page 4

background image

4

F

RIGHT RETURN STRAIGHT DISCHARGE

FRONT

L

N

O

M

RIGHT RETURN

FRONT

LEFT/STRAIGHT
DISCHARGE

CSP

BACK

DISCHARGE

CONDENSATE

3 / 4" FPT

3.3"

[83.8 MM]

0.7"

[17.8 MM]

FRONT-VIEW

E

D

K

J

2

1

1.1 [27.9 MM]

A

CAP

BSP

RIGHT RETURN RIGHT VIEW -

AIR COIL OPENING

AIR COIL

C

T

S

B

R

Q

FRONT

L

N

O

M

LEFT RETURN STRAIGHT DISCHARGE

FRONT

BSP

LEFT RETURN

RIGHT RETURN

AIR COIL

CSP

FRONT

LEFT RETURN LEFT VIEW -

AIR COIL OPENING

1.75 [44.5 MM]

C

T

R

Q

S

B

UNIT HANGER DETAIL

U

V

FRONT

W

MODEL

U V W

015-030 43.1 [109.5] 22.2 [56.4] 18.0 [45.7]
036-042 47.1 [119.6] 22.2 [56.4] 18.0 [45.7]
048-060 54.1 [137.4] 26.2 [66.5] 22.0 [55.9]

RIGHT RETURN BACK DISCHARGE

A

AIR COIL

S

IDE

C

P

N

O

M

CSP

BSP

2 FT [610 MM] SERVICE

ACCESS

FRONT

LEFT RETURN

0.7" [17.8 MM]

3.3"
[83.8 MM]

CSP

CONDENSATE

3 / 4" FPT

2 FT [610 MM] SERVICE

ACCESS

AIR COIL

S

IDE

M

A

C

LEFT RETURN BACK DISCHARGE

N

O

P

BSP

BLOWER

OUTLET

BLOWER

OUTLET

BLOWER

OUTLET

BLOWER

OUTLET

OPTIONAL 2 FT

[610 MM]

SERVICE

ACCESS

OPTIONAL 2 FT

[610 MM]

SERVICE

ACCESS

G

H

006-012 34.1 [86.6] 21.1 [53.6] 18.9 [42.9]

NOTE: BLOWER SERVICE PANEL REQUIRES 2 FT SERVICE ACCESS

POWER SUPPLY

3 / 4" [19.1 MM] KNOCKOUT

1 / 2"

[12.7 MM]

KNOCKOUT

LOW VOLTAGE
1 / 2" [12.7 MM]

KNOCKOUT

3

RIGHT/STRAIGHT

DISCHARGE

BACK

DISCHARGE

NOTE: CHOOSE EITHER
BACK OR STRAIGHT DISCHARGE

NOTE: CHOOSE EITHER

BACK OR STRAIGHT DISCHARGE

50PCH006-060 UNITS

NOTES:

1. While clear access to all removable panels is not required, installer should

take care to comply with all building codes and allow adequate clearance
for future field service.

2. Horizontal units shipped with filter bracket only. This bracket should be

removed for return duct connection.

3. Discharge flange and hanger brackets are factory installed.
4. Condensate is

3

/

4

-in. (19.1 mm) FPT copper.

5. Blower service panel requires 2 ft (610 mm) service access.
6. Blower service access is through back panel on left or right discharge units

or through panel opposite air coil on back discharge units.

50PCH

UNIT

SIZE

OVERALL CABINET

WATER

CONNECTIONS

ELECTRICAL KNOCKOUTS

DISCHARGE CONNECTIONS

DUCT FLANGE

(

0.10 in., 2.5 mm)

RETURN CONNECTION

USING RETURN AIR

OPENING

A

Width

B

Depth

C

Height

1

2

3

4

Size

(IPT)

H

1

/

2

-in.

J

1

/

2

-in.

K

3

/

4

-in.

L

M

Supply

Height

N

Supply

Width

O

P

Q

Return

Depth

R

Return

Height

S

T

Loop In

Loop Out

D

E

F

G

Low

Voltage

Low

Voltage

Power

Supply

006-

012

in.

19.1

34.1

11.1

9.6

1.1

1.5

1.1

1

/

2

8.1

5.1

2.1

0.8

8.9

6.7

8.2 1.3

16.1

9.8

1.1 0.6

cm

48.5

86.6

28.2

24.3

2.7

3.8

2.7

1.3

20.6

13.0

5.4

1.9

22.7

17.0

13.3 3.3

41.0

25.0

2.7 1.5

015

in.

20.1

43.1

17.0

15.1

1.4

3.2

1.4

1

/

2

12.1

9.1

6.1

2.6

13.3

9.9

4.1 1.3

23.0

15.0

1.1 1.0

cm

51.1

109.5

43.2

38.4

3.4

8.1

3.5

1.3

30.8

23.2

15.6

6.6

33.8

25.1

10.5 3.3

58.4

38.1

2.8 2.5

018

in.

20.1

43.1

17.0

15.1

1.4

4.1

1.4

1

/

2

12.1

9.1

6.1

2.6

13.3

9.9

4.1 1.3

23.0

15.0

1.1 1.0

cm

51.1

109.5

43.2

38.4

3.4

10.4

3.5

1.3

30.8

23.2

15.6

6.6

33.8

25.1

10.5 3.3

58.4

38.1

2.8 2.5

024

in.

20.1

43.1

18.3

15.1

1.4

4.4

1.4

3

/

4

12.1

9.1

6.1

2.6

13.3

9.9

4.1 1.3

23.0

16.3

1.1 1.0

cm

51.1

109.5

46.5

38.4

3.4

11.3

3.5

1.9

30.8

23.2

15.6

6.6

33.8

25.1

10.5 3.3

58.4

41.4

2.8 2.5

030

in.

20.1

43.1

18.3

15.1

1.4

3.1

1.4

3

/

4

12.1

9.1

6.1

2.6

13.3

9.9

4.1 1.3

23.0

16.3

1.1 1.0

cm

51.1

109.5

46.5

38.4

3.4

7.8

3.5

1.9

30.8

23.2

15.6

6.6

33.8

25.1

10.5 3.3

58.4

41.4

2.8 2.5

036

in.

20.1

47.1

21.0

15.1

1.4

5.3

1.4

3

/

4

16.1

13.1

10.1

2.5

16.1

11.0

3.0 2.5

25.9

19.0

1.1 1.0

cm

51.1

119.6

53.3

38.4

3.4

13.4

3.5

1.9

41.0

33.3

25.7

6.3

40.9

27.9

7.7 6.4

65.8

48.3

2.8 2.5

042

in.

20.1

47.1

21.0

15.1

1.4

4.4

1.4

3

/

4

16.1

13.1

10.1

2.5

16.1

11.0

3.0 2.5

25.9

19.0

1.1 1.0

cm

51.1

119.6

53.3

38.4

3.4

11.3

3.5

1.9

41.0

33.3

25.7

6.3

40.9

27.9

7.7 6.4

65.8

48.3

2.8 2.5

048

in.

24.1

54.1

21.0

15.1

1.4

4.4

1.4

1

16.1

13.1

10.1

3.7

16.1

13.7

4.1 1.3

35.9

19.0

1.1 1.0

cm

61.2

137.4

53.3

38.4

3.4

11.1

3.5

2.5

41.0

33.3

25.7

9.5

41.0

34.8

10.3 3.2

91.2

48.3

2.8 2.5

060

in.

24.1

54.1

21.0

15.1

1.4

3.8

1.4

1

16.1

13.1

10.1

1.7

18.1

13.7

4.1 1.3

35.9

19.0

1.1 1.0

cm

61.2

137.4

53.3

38.4

3.4

9.7

3.5

2.5

41.0

33.3

25.7

4.4

46.0

34.8

10.3 3.2

91.2

48.3

2.8 2.5

Fig. 1 — 50PCH Unit Dimensions

a50-8695

LEGEND

BSP — Blower Service Panel
CAP — Control Access Panel
CSP — Compressor Service Panel
FPT — Female Pipe Thread