Technical data, continued, Technical data 96 – Leica Geosystems TPS110C User Manual
Page 96

Technical Data
96
Technical Data, continued
Distance measurement (RL: reflectorless)
•
Type
visible red laser
•
Carrier wavelength
0.670 µm
•
Measuring system
special frequency system
basis 100 MHz 1.5 m
•
EDM type
coaxial
•
Display (least count)
1 mm
•
Laser spot size:
approx. 7 x 14 mm / 20 m
ca. 10 x 20 mm / 50 m
•
Range of measurement:
1.5 m to 80 m
(to target plate art.no. 710333)
•
Prism constant:
+ 34.4 mm
Beam interruptions, severe heat shimmer
and moving objects within the beam path
can result in deviations from the specified
accuracy.
EDM measuring
program
Time per measurement
RL-Standard
3.0 sec. +1.0 sec./10m > 30m
RL-Track
1.0 sec. +0.3 sec./10m > 30m
Atmospheric
conditions
No reflector
(white target)*
No reflector
(gray, albedo 0.25)*
4
60 m (200 ft)
30 m (100 ft)
5
80 m (260 ft)
50 m (160 ft)
6
80 m (260 ft)
50 m (160 ft)
Range
•
Accuracy (Standard deviation acc. to ISO 17123-4)
The distance measuring accuracy is 5mm +
3ppm for the listed EDM measuring programs
(6mm @ 300m; 1/4 inch @ 1500ft).
*
Kodak Grey Card used with exposure meter
for reflected light
4) Object in strong sunlight, severe heat shimmer
5) Object in shade, or sky overcast
6) Day, night and twilight