beautypg.com

Technical data, continued, Technical data 96 – Leica Geosystems TPS110C User Manual

Page 96

background image

Technical Data

96

Technical Data, continued

Distance measurement (RL: reflectorless)

Type

visible red laser

Carrier wavelength

0.670 µm

Measuring system

special frequency system

basis 100 MHz 1.5 m

EDM type

coaxial

Display (least count)

1 mm

Laser spot size:

approx. 7 x 14 mm / 20 m

ca. 10 x 20 mm / 50 m

Range of measurement:

1.5 m to 80 m

(to target plate art.no. 710333)

Prism constant:

+ 34.4 mm

Beam interruptions, severe heat shimmer
and moving objects within the beam path

can result in deviations from the specified
accuracy.

EDM measuring

program

Time per measurement

RL-Standard

3.0 sec. +1.0 sec./10m > 30m

RL-Track

1.0 sec. +0.3 sec./10m > 30m

Atmospheric

conditions

No reflector

(white target)*

No reflector

(gray, albedo 0.25)*

4

60 m (200 ft)

30 m (100 ft)

5

80 m (260 ft)

50 m (160 ft)

6

80 m (260 ft)

50 m (160 ft)

Range

Accuracy (Standard deviation acc. to ISO 17123-4)
The distance measuring accuracy is 5mm +
3ppm for the listed EDM measuring programs
(6mm @ 300m; 1/4 inch @ 1500ft).

*

Kodak Grey Card used with exposure meter
for reflected light

4) Object in strong sunlight, severe heat shimmer
5) Object in shade, or sky overcast
6) Day, night and twilight