3. Ensure that the screen is at its full brightness level. To do this, enter the menu system by

pressing any button and press DIM and increase the brightness until it will not increase
anymore.

4. Let the unit remain on for 2 hours.
5. If, after these 2 hours, your EFIS-D6 has not turned off and does not display the

INTERNAL BATTERY LOW warning, your battery passes the capacity test.

6. Make sure you recharge your battery; a full charge is reached when the voltmeter shows

at least 16.0 volts on the internal battery.

If your battery does not pass the above test, please contact Dynon Avionics and refer to
Appendix E for battery replacement instructions.

FIRMWARE UPGRADE

Dynon Avionics provides free firmware updates for all its products, and continues to add new
features periodically. We suggest that you regularly ensure that your EFIS-D6 has the latest
firmware by visiting our website at

downloads.dynonavionics.com

and downloading the latest

Dynon Product Support Program. This software contains the latest firmware updates for all our
products.
The EFIS-D6 is upgraded by connecting a PC to the EFIS-D6’s serial port and starting the
Dynon Support Program on the PC.

DISPLAYED ALERT MESSAGES

The following table describes the alert messages that the EFIS-D6 can display.

Alert Message

Description

End condition

INTERNAL
ERROR
SERVICE UNIT

This error can occur for a few
reasons, including an aborted upload.
It signifies that the EFIS-D6 has
detected internal problems in its
firmware or calibration tables.

When this error appears, it may be
possible to recover your unit in the
field. The best way of ensuring this
is to call Dynon Avionics
immediately. However, there is a
good possibility that the unit will
have to be returned for service.