5. APPENDIX
The appendices contain additional information pertaining to the installation and maintenance of
the EFIS-D6. You will find here a table of weights, specifications, a configuration table, the
maintenance manual, the OAT Installation and Operating Guide, the AOA Pitot Installation
Guide, and the Blind encoder Serial-to-Parallel Installation Guide.
Appendix A: Instructions for Continued Airworthiness
INTRODUCTION
This section gives the installer or mechanic information pertaining to maintenance of the EFIS-
D6. Additionally, it provides the steps necessary to ensure continued airworthiness for the unit.
CAUTION
With the exception of replacing the internal emergency battery, the EFIS-D6 contains no user-
serviceable parts. Refer all servicing to Dynon Avionics.
INSTRUCTIONS FOR CONTINUED AIRWORTHINESS
Other than for regulatory periodic checks and an annual internal battery capacity test (if optional
internal emergency battery is installed), maintenance of the EFIS-D6 is “on-condition” only.
With the exception of the battery, periodic maintenance of the EFIS-D6 is not required.
ALTIMETER CHECK
The following test can be performed on an as-needed basis. If the altimeter is found to be out of
specification, the following single-point adjustment can be performed by navigating the menus to
SETUP > ALTADJ. In the Altimeter Adjustment menu, you can change the displayed altitude by
up to 500 feet up or down. After making this adjustment, ensure that the altimeter on the EFIS-
D6 meets the tolerances allowed between 0 and 30,000 feet. If this adjustment does not bring the
altimeter on the EFIS-D6 to within specification at all attitudes, please contact Dynon Avionics
to return for service.
INTERNAL BATTERY CHECK
If your EFIS-D6 has a rechargeable Internal Backup Battery, it is necessary to ensure that the
battery capacity is such that it will last at least 2 hours on a full charge. At least once per year,
perform the following test.
1. With the EFIS-D6 drawing power from an external source, allow it to charge its Internal
Backup Battery above 16.0 volts. Observe the voltmeter (to display, use SETUP >
CLUTTR > VMETER). The battery may charge to as high as 16.8 volts, but it is only
necessary to charge it to 16.0 volts for this test.
2. Remove all sources of external power from the EFIS-D6, ensuring that it is operating off
its Internal Backup Battery.
EFIS-D6 Installation Guide