5 port default settings, 6 power connectors, 1 power requirements – CANOGA PERKINS 9145EMP Network Interface Device Hardware User Manual
Page 22: 2 single ac power base unit
9145EMP Network Interface Device Hardware User’s Manual
Functional Description
Port Default Settings
10
2.5 Port Default Settings
Table 2-3 represents the default settings for each of the ports. The term active connector refers to
the connector, either UTP or SFP, that is currently enabled. For example, if a particular 9145EMP
model has a User Port with both UTP and SFP connectors present, by default the UTP is the
Active Connector (it can currently transmit and receive data), while the SFP is the Inactive Con-
nector (that is, it currently cannot transmit or receive data).
Table 2-3 Default Port Settings
NOTE: Cells in yellow denote connectors that are active by default.
2.6 Power Connectors
The 9145EMP will accommodate both single and redundant AC and DC powering options, along
with mixed AC and DC power.
2.6.1 Power Requirements
100 VAC to 240 VAC (auto-ranging), 50/60 Hz, 0.5 Amps (9145EMP only)
36 VDC to 72 VDC, 1.0 Amps
18 VDC to 36 VDC, 2.0 Amps
2.6.2 Single AC Power Base Unit
The Single AC powered 9145EMP base unit (Figure 2-4) has an IEC 320 power connector on the
rear panel. An appropriate AC power cord is supplied with the unit.
Figure 2-4 Single AC Power
UTP
SFP w/ 100
Mbps Optics
SFP w/ 1000 Mbps
Optics
SFP w/ Multispeed
Optics (100 to 1000)
User Ports
Auto
100 FD
1000 FD
1000 FD
Network Ports
N/A
100 FD
1000 FD
1000 FD
OOB Ports
Auto
N/A
N/A
N/A