EdgeAccess Universal Chassis System

Model 1502 Domain Management Module

3-8

The MAC or Ethernet hardware address for the DMM is fixed. If BOOTP is enabled during the
initialization process, it broadcasts BOOTP request packets until it receives a response from the
BOOTP server or you press to continue. If the DMM has a fixed IP address, disable
BOOTP. To assign an IP address to the DMM through the BOOTP request process, follow these
steps:

1. At the Domain Management Module menu, type

1

; the System Configuration screen appears.

2. Check item 10, BOOTP.

• If it is set to "Yes," reset the DMM to start the BOOTP process.
• If it is set to "No," follow these steps:

a. Type

10

; the BOOTP Options screen appears.

b. Type

Y

to enable BOOTP. The next time you reset the DMM, it will start the BOOTP

process.

3. To return to the Domain Management Module menu, press .

Manage Traps and Alarms

Traps are messages that require management attention and are routed to the Network Manager
and the DMM Alarm Log, but do not trigger alarms. Use the Trap Configuration screen to view
the current configuration and to enable or disable traps for the DMM. For a list of events that
trigger traps, see Table 7. To set up the traps, follow these steps:

1. At the Domain Management Module menu, type

5

, "Trap Configuration," and press .

2. At the Trap Configuration screen, type the number for a trap and press . See Table 7.

3. Press to cycle to Enabled or Disabled and press .

4. To return to the Domain Management Module menu, press .

These selections do not affect how the CIM Major and Minor LEDs report alarms.

Table 7. Trap Configuration Options

Trap

When enabled, sends a Trap if. . .

Cold Start

The DMM is reset by a power failure or forced reset

Setup Error

The DMM is set up incorrectly

Fan/Power/Over Temperature The chassis power supply or fan malfunctions or the temperature is too

high

Chassis On/Off Line

The chassis in the domain does not respond

Module Insert/Removed

A module is inserted or removed

Authentication Error

An unauthorized host attempts SNMP access to the DMM

Chassis Power Exceeded

The installed modules draw more total power than the chassis supplies