Interconnect Feature

Your Combination Smoke/CO Alarm is interconnectable to other

multiple station Kidde, Nighthawk and Kidde/Fyrnetics products:
• When compatible smoke alarms and heat alarms are

interconnected to your Smoke/CO Alarm, they will only
respond to a smoke related event.

• When mixing compatible models with battery backup with models

without battery backup, be advised that the models without battery
backup will not respond during an AC power failure.

• This unit is only approved to interconnect with other

Kidde/Nighthawk products. It is NOT approved to interconnect

with any other brand of detection product.

• This alarm is interconnect compatible with the following alarms

and accessories:

–Smoke alarms: 1235, 1275, 1276, 1285, i12020, i12020A,

i12040, i12040A, i12060, i12060A, i12010SCO, i12010S,

i4618, i4618A, KN-SMFM-I, RF-SM-ACDC, PE120, P12040,

Pi2000, Pi2010, i12080, i12080A, KN-COSM-I, KN-COSM-
IB, KN-COSM-IBA

– Heat alarm: HD135F
– CO alarms: KN-COB-IC, KN-COP-IC, KN-COPE-I

– Relay modules: SM120X, CO120X
– Strobe Light: SL177i, SLED177i

• For more information about compatible interconnect units and

their functionality in an interconnect system, visit our web site
at www.kidde.com.

Smoke HUSH Control Feature

The HUSH feature has the capability of temporarily desensitizing
the smoke alarm circuit for approximately 9 minutes. This feature
is to be used only when a known alarm condition, such as smoke
from cooking, activates the alarm. When the unit is in alarm,You
can put your Smoke/CO Alarm in HUSH mode by pushing the
test/reset button. If the smoke is not too dense, the alarm will
silence immediately, the unit will verbally announce “HUSH
MODE ACTIVATED”, and the green LED will flash every 2 seconds
for approximately 9 minutes. This indicates that the smoke alarm
is in a temporarily desensitized condition. Your Smoke/CO Alarm
will automatically reset after approximately 9 minutes. When the
unit returns to normal operation after being in HUSH mode, it
will verbally announce “HUSH MODE CANCELLED”, and sound
the alarm if smoke is still present. The HUSH feature can be used
repeatedly until the air has been cleared of the condition causing
the alarm. While the unit is in HUSH mode, pushing the test/reset
button on the alarm will also end the HUSH period.