heat or cold can be transferred from the outside to the inside
through poorly insulated walls and roof.

This may cause a

thermal barrier, which can prevent smoke from reaching an alarm
mounted on the ceiling.

In such mobile homes install your

Smoke/CO Alarm on an inside wall with the top edge of the
alarm at a minimum of 4 inches (10cm) and a maximum of 12
inches (30.5cm) below the ceiling (see figure 2). If you are not
sure about the insulation in your mobile home, or if you notice
that the outer walls and ceiling are either hot or cold, install your
alarm on an inside wall ONLY!

THIS EQUIPMENT SHOULD BE INSTALLED IN ACCORDANCE
WITH THE NATIONAL FIRE PROTECTION ASSOCIATION’S
STANDARD 72 (National Fire Protection Association,
Batterymarch Park, Quincy, MA 02269).

B. Where Not to Install:

Do not install in garages, kitchens, furnace rooms or
bathrooms! INSTALL AT LEAST 5 FEET AWAY FROM ANY
FUEL BURNING APPLIANCE.

Do not install within 3 ft (.9m) of the following: The door to a
kitchen, or a bathroom that contains a tub or shower, forced air
supply ducts used for heating or cooling, ceiling or whole house
ventilating fans, or other high air areas. Avoid excessively dusty,
dirty or greasy areas. Dust, grease or household chemicals can
contaminate the alarm's sensors, causing it to not operate
properly.

Place the alarm where drapes or other objects will not block the
sensor. Smoke and CO must be able to reach the sensors to
accurately detect these conditions. Do not install in peaks of
vaulted ceilings, “A” frame ceilings or gabled roofs. Keep out of
damp and humid areas.

Installation Instructions

10

WARNING

-

This product is intended for

use in ordinary indoor locations of family
living units. It is not designed to measure
compliance with Occupational Safety and
Health Administration (OSHA) commercial
or industrial standards.

!