Rane THX Room EQ User Manual
Page 7
![background image](/manuals/650071/7/background.png)
Home THX Equalization Manual Rev. 1.5
7
•
Choose four positions that represent prime listening positions spaced equally throughout the
listening area (Fig. 1).
•
Position your analyzer’s microphones at seated ear height (38" to 48" off finished floor). Place the
microphone(s) on a stand.
•
Do not attach any microphone directly to the analyzer or hold it in your hand. Your body is an
acoustical object large enough to influence what is supposed to be a room measurement.
•
Label in your notes each position and note any related information (e.g., Microphone 3 located
under loft overhang) which can affect your interpretation of the measurements.
•
Do not point any microphone directly at a loudspeaker. Point it straight up. You are looking for a
room measurement, not just the direct field of the loudspeaker.
•
If you are placing a microphone on any piece of furniture (i.e., a chair or couch), make sure that
the mic is away from any cushion or seat back by at least 1 foot. This will improve the accuracy of
measurements at that position above 800 Hz.
For multiple rows of seats, see Fig. 2 below.
Mic Positions
1
2
3
4
Multiple Row Seating and Microphone Positions
Fig 2