Page 4

background image

Manual-

Front Panel Description

Analyzer display LEDs

are in a 5 by 30 array (3 color).

0 dB point

is for VU meter mode (SOURCE=LINE IN, GAIN to +4 dBu or -10 dBV, METER/RTA button=METER).

0 dB point

is for SPL meter mode (SOURCE=CAL MIC, GAIN to center detent, METER/RTA button=METER). See the

Range indicator , i.e., if the 100 Range LED is on, then the 0 dB LED = 100 dB SPL.

WEIGHT button:

provides user-selectable A- or C-weighting in SPL meter mode. The A-curve is a wide bandpass filter cen-

tered at 2.5 kHz, with ~20 dB attenuation at 100 Hz, and ~10 dB attenuation at 20 kHz, therefore it tends to heavily roll-off the

low end, with a more modest effect on high frequencies. It is the inverse of the 30-phon (or 30 dB-SPL) equal-loudness curve of

Fletcher-Munson. The C-curve is “flat,” but with limited bandwidth, with -3 dB corners of 31.5 Hz and 8 kHz, respectively.

SPL Range indicators: in 120 dB, 100 dB, or 80 dB maximum. The Cal Mic Input auto ranges for optimum operation.

NORMAL (Normalize) button:

sets the 0 dB reference to the maximum level in RTA mode, to help center the display.

Second function: Enables or disables the Peak Hold function in VU meter mode.

Third function: Displays the firmware version when the SOURCE switch is set to OFF. The top row number of LEDs illuminated

is the major version, the bottom row of illuminated LEDs is the minor version.

SCALE button:

User selectable ±1, ±3 & ±6 dB per row. For instance, in the ±3 dB position, the yellow LED in each band lights

when signals of that frequency are over +3 dB or below -3 dB, and the red LEDs light at +6 dB and -6 dB.

PINK NOISE button:

Engage to activate the built-in pink noise generator. Be sure your system is turned down before engaging this

switch to prevent scaring yourself. The LED glows to remind you when pink noise is active.

METER / RTA button:

Toggles between the RA 30 performing meter functions, or RTA functions. The corresponding LED

lights to let you know which function is active. The SPL function is only active when CAL MIC is selected and this switch is set to

METER.

0

OL / SIG indicators:

Signal and Overload alerts for the currently selected input. Adjust the GAIN control so the OL light does

not come on.

q

GAIN control:

In SPL meter mode, the RA 30 is calibrated when using Rane's MIC 2 on the CAL MIC Input and the GAIN

control is in center detent position. In VU meter mode, the RA 30 is calibrated to +4 dBu nominal signal (0 dB on VU scale)

when the GAIN control is in center detent position, and calibrated to -10 dBV nominal signal (0 dB on VU scale) when the

GAIN control is in full clockwise position. The gray labels pertain to VU meter mode.

w

SOURCE selector:

A single front panel selector switch chooses which input is fed to the RA 30:

1. OFF: No input selected.

2. CAL MIC: unbalanced, auto gain ranging, XLR-female front panel jack. Uses Rane's MIC 2.

3. LINE IN: balanced/unbalanced ¼" jacks on rear. For mono VU meter function, plug only into the left input.

4. AUX MIC: uncalibrated, balanced, rear panel trim control 15 to 45 dB gain range, rear panel OL LED

e

CAL MIC Input jack: PLUG ONLY THE RANE MICROPHONE INTO THIS JACK – THE DC VOLTAGE SUPPLIED

BY THIS JACK COULD DAMAGE ANY OTHER MICROPHONE.

USE RANE

MIC ONLY!

ANALYZER

REALTIME

RA 30

GAIN

CAL MIC

SOURCE

0 dB

METER

RTA

SCALE

NORMAL

1

3

6

120

100

80

WEIGHT

C

A

RTA

METER

NOISE

PINK

VU

SPL

SIG

OL

+12

-12

CAL

-5

-27

-30

-24

-25

-21

-15

-18

-20

-12

-9

-15

-6

-3

-10

+3

+12

+6

+9

0

dB

dB

6.3k

50

25 31.5 40

160

63

80

125

100

315

200 250

400 500

1k

800

630

1.25k 1.6k

3.15k

2.5k

2k

4k

5k

20k

8k

10k

16k

12.5k

CAL

MIC

AUX

MIC

OFF

LINE

IN

0 dB

VU METER MODE

0 dB

SPL METER MODE