beautypg.com

Rw manual-31 – Rane ECS v2 RaneWare (RaneWare 2.1) User Manual

Page 31

background image

RW Manual-31

Get Expansion Revisions (0A hex):
Transmit ADDR header ($FB xx FB xx, where xx = ADDR)
Get DT
Get ID
Transmit $00 $02 (where $00 02 = number of data bytes to follow including checksum)
Transmit $0A (command code)
Transmit $F4 (Checksum)
Get Expansion Revisions (7 bytes are returned. Byte 1 = software revision of ECB 62, byte 2 = software revision of 1

st

ECM

82, byte 3 = software revision of 2

nd

ECM 82, ... , byte 7 = software revision of 6

th

ECM 82. A zero in any byte 2 7 indicates

that the corresponding ECM 82 is not connected.)

Get Checksum
Get COMSTAT

Get Output Names ($0C)
Transmit ADDR header ($FB xx $FB xx,where xx = ADDR) (See Note 9)
Get DT
Get ID
Transmit $00 $04 (where $00 $04 = number of data bytes to follow through the start parameter)
Transmit $07 (command code)
Transmit the Name Index (0 = Beginning of the first name)
Transmit the number of Name Indexes ($30 = all names)
Transmit the checksum
Get SNPL
Get Checksum
Get COMSTAT

Reset Unit (91 hex):
Transmit ADDR header ($FB xx FB xx, where xx = ADDR)
Get DT
Get ID
Transmit $00 $03 (where $00 02 = number of data bytes to follow including checksum)
Transmit $91 (command code)
Transmit RESET ($00 = Reset unit, $01 = Reset unit and set all data to default)
Transmit Checksum
Get COMSTAT