beautypg.com

Additional ucm features – Wilbur Curtis D60GT30 User Manual

Page 4

background image

4

Tank Temperature Check

Turn on brewer at the control panel ON/OFF button. Press and hold 3 button (see illustration, page 2) for 5 seconds. Water Temperature will be displayed.

Brew Volume – Easy Access

– Not on Used on Model TA-60

Units produced beginning January 2008 can be easily adjusted from the front panel. Written into the software on the D60GT UCM, is a feature to access the

brew volume without entering the program mode.

The UCM must be on. To adjust the D60GT model, press and hold down the center, Select button 2 . The screen will read

pressing < or

> will adjust the brew volume up or down, ± 20 oz, in 1 ounce increments.

ADDITIONAL UCM FEATURES

Beeper On/Off (Factory set to ON)

Press  to display ON or OFF. Pressing either < or > toggles between on and off.  to set.
Pulse Brew (Factory setting OFF)

Press  to select, < or > to select OFF or one of four pulse patterns (A to E) .
Guidelines for Pulse Brew:

This feature allows tuning of the coffee flavor. The pot level should always be set first with this option OFF. Depending on your

grind profile and water conditions, the five Pulse Brew options help “tune” or change the coffee flavor. Filter Pack type coffees

typically extract better with the A and B pulse setting. Decaffeinated coffees typically extract better with the B pulse setting. High-

Yield coffees typically extract better with the C pulse setting. Of course, any of the A, B or C settings may be used to suit your taste

profile. There are two additional settings (D and E) that allow you to manually set the ON TIME pulses and OFF TIME.

If Pulse Brew is selected (ON), Cold Brew Lock is set to Delta 1 within 5ºF of set point and Cold Brew Lock does not ap-

pear the list of program selections. When Pulse Brew is ON, Pre-infusion disappears from the list of program selections.

Display Brew Time (Factory set to ON)

Press  to display ON or OFF. Pressing either < or > toggles between on and off.  to set. When on, the Display Brew Time fea-

ture allows you to see the remaining time in the brewcyle counting down.
Drip-Out Mode (Factory set to 2 min)

Press  to select. Press > to increase time (to a maximum of 5 minutes) or < to decrease the time and turn OFF. Time counts up

in 5 second increments. Press  to set.
Display Messages (Factory set to ON)

Press  to turn ON or OFF. The message displayed is “Rinse Server Before Brewing”. This message will alternate; two seconds

with Rinse Server Before Brewing, then Curtis READY TO BREW will appear for six seconds.
Language (Factory set to English)

Pressing < or > toggles between English and French. Press  to set.
Model Select

Press  to select, < or > to select model. The selections are: ALPHA-1, ALPHA-2, ALPHA-3/4/5, Airpot Brewer, Thermo-Alpha (for

the D60GT). Press  to set. When the Model Select feature is changed, all settings are reset to the defaults of the newly selected

model.
Exit

Press  to select, exits program mode and returns unit to operation.

This manual is related to the following products: