Pre-Infusion (Factory set to OFF)

Press  to Select. Current setting in seconds is displayed < to decrease or select > to increase (range from OFF to 10 through

60 seconds),  to set.

If Pre-infusion is selected (ON), Cold Brew Lock is set to Delta 1 within 5ºF of set point and Cold Brew Lock is disappears

from the list of program selections. When Pre-infusion is ON, Pulse Brew disappears from the list of program selections.

Quality Timer (Factory set to OFF) Press  to Select, < or > OFF or ON 20 minutes to 120 minutes in 10 minute increments.

Press  to set. An audible alarm will sound when time is expired.

Brew Count Total

Press  to Select, Shows total gallons and total brew cycles on the unit. Brew Count Total cannot reset.

Cold Brew Lock . . . (Factory set to 15º)

Press  to select, < or > to select desired setting (CBL 5, 15 or OFF), to set.

Master Reset

Press  to display Are You Sure? Then < for Yes, > for No. Brewer factory defaults are then reset.
Service Call (Phone number Factory set to 1-800-000-0000x)

Press  to display number and change number or < to move place and EX to exit when complete This number will be displayed

during a Heating system SENSOR ERROR or during a WATER ERROR.
Access Code (Factory set to 1-2-3-4)

Press  to display number and change number, (the number can be change 1 to 4) or < to move place and ex to exit when com-

plete.
Banner Name (Factory set to Curtis)

Press  to display letters and change letters or < to move place and EX to exit when complete. This feature allows up to 14 letters

to be programmed for company name or regional name. Programming all blanks disables Banner Name. If programmed, Banner

Name is displayed every 5 sec. on and off.
P-Maintenance (Factory set to OFF)

Press  to Select, Set gallons brewed to indicate P-Maintenance. Press < or > to adjust from Off to 3000 gallons. Press  to exit.

Brew Volume

Selecting Brew by Volume or Brew by Time depends on whether you know your brew time before starting. From Program Menus

press > display will now show the next feature.

During the actual brew cycle, a 2-minute drip mode is added to the brew time. The programmed water level compensates

for back to back brewing Delta 3 to allow for an increase of water volume.

Brew by Volume (Factory set to 60 oz.)

Press  to Select, Display will now show Push START To Begin... Press the BREW button then hot water starts running, when

desired volume is reached press BREW button again to stop the flow. Now the volume has been set. Pressing > button will display

the subsequent menu features.
Brew by Time (Factory set to 2 min – 20 sec).

Press  to Select to change the brew time. Display will now show the current time. By pressing < or > you can toggle back and

forth from minutes to seconds to exit (ex). Change the time or set and exit by pressing .
Temperature (Factory set to 200°F)

Press  to Select. Press < or > to move to desired temperature and then  to set. Temperature is programmable from 170ºF to

206ºF in 2-degree increments.
Energy Save Mode (Factory set to OFF)

Press  to Select, < or > ON, OFF or ON 140ºF,  to set. When in ON, unit will automatically shut off 4 hours from last brew.

When feature is OFF, unit does not have the energy saving mode. In the ON 140ºF position, temperature goes down to 140ºF if

unit has not brewed in 4 hours. This feature will save energy by lowering the tank temperature during periods of non-operation.
Brew Count Odom.

Press  to display total gallons brewed. Press ex or Reset

PROGRAM MENUS

Model Select – Always perform this first. This feature re-sets all settings to the factory defaults.

Scroll through menu to Model Select. Choices are ALPHA-1, ALPHA-2, ALPHA-3/4/5, Airpot Brewer and Thermo-Alpha.

Select only Thermo-Alpha.

The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the actual set point. The first

setting is within 5 degrees of set point, next is within 15 degrees of set point, OFF is within 30 degrees of set point for the Ready

to Brew message, however it will brew at any temperature. This feature will operate after initialization to set temperature after the

rear standby toggle switch is reset to ON.