Metalfab Hindon-Invicta L Series User Manual
Page 11
![background image](/manuals/646372/11/background.png)
9
Vibrator Model
Relub. Interval *
(Hours)
Grease Amount
Per Brg. (Ounces)
Initial Grease Fill
Per Brg. (Ounces)
2 Pole
BL 24/25-10/2
1600
0.2
0.4
BL 24/25-13/2
1400
0.3
0.6
BL 30 ALL
700
0.4
0.9
BL 40-30/2
650
0.5
1.2
BL 40-40/2
600
0.7
1.9
BL 50-50/2
200
0.6
2.8
4 Pole
BL 24/25-11/4
3500
0.2
0.4
BL 24/25/-14/4
3300
0.3
0.6
BL 30 ALL
3100
0.5
1.1
BL 40-35/4
2700
0.6
1.4
BL 45-45/4
2200
0.8
2.1
BL 50-55/4
1800
1.1
3.2
BL 50-65/4, -75/4
1600
1.3
3.9
BL 60 ALL
800
1.7
5.6
BL 75-130/4
350
1.3
7.1
6 Pole
BL 24/25-8/6
5800
0.2
0.4
BL 24/25-11/6
4800
0.3
0.6
BL 30 ALL
5000
0.5
1.1
BL 40 ALL
4300
0.7
1.4
BL 45 ALL
4100
0.9
2.1
BL 50-60/6
3800
1.1
3.2
BL 50-75/6
3400
1.3
3.9
BL 60 ALL
2600
1.9
5.6
BL 75 ALL
1800
2.3
7.1
8 Pole
BL 30 ALL
7000
0.5
1.1
BL 40-17/8
6500
0.7
1.4
BL 45 ALL
6000
0.9
2.1
BL 50-45/8
5500
1.1
3.2
BL 50-57/8
5000
1.1
3.9
BL 60 ALL
4500
2.1
5.6
BL 75-150/8
3000
2.3
7.1
* Relubrication intervals are based on continuous operation in ambient temperatures up to 68°F
(20° C) and should be reduced for increases in ambient temperature as follows: 77°F (25° C) x
.8, 86°F (30° C) x 0.65, 95°F (35° C) x 0.5, 104°F (40° C) x 0.4. Above 104°F (40° C) consult
our Technical Department.
Factory recommended grease for Invicta vibrators is EXXON UNIREX N2 or N3.
NOTE: The above relubrication intervals are for guidance only and may be shortened or
lengthened, if necessary, in view of actual field experience by the end user.
Table 3: Bearing Relubrication Intervals and Amounts