beautypg.com

Metalfab Hindon-Invicta L Series User Manual

Page 11

background image

9

Vibrator Model

Relub. Interval *

(Hours)

Grease Amount

Per Brg. (Ounces)

Initial Grease Fill

Per Brg. (Ounces)

2 Pole
BL 24/25-10/2

1600

0.2

0.4

BL 24/25-13/2

1400

0.3

0.6

BL 30 ALL

700

0.4

0.9

BL 40-30/2

650

0.5

1.2

BL 40-40/2

600

0.7

1.9

BL 50-50/2

200

0.6

2.8

4 Pole
BL 24/25-11/4

3500

0.2

0.4

BL 24/25/-14/4

3300

0.3

0.6

BL 30 ALL

3100

0.5

1.1

BL 40-35/4

2700

0.6

1.4

BL 45-45/4

2200

0.8

2.1

BL 50-55/4

1800

1.1

3.2

BL 50-65/4, -75/4

1600

1.3

3.9

BL 60 ALL

800

1.7

5.6

BL 75-130/4

350

1.3

7.1

6 Pole
BL 24/25-8/6

5800

0.2

0.4

BL 24/25-11/6

4800

0.3

0.6

BL 30 ALL

5000

0.5

1.1

BL 40 ALL

4300

0.7

1.4

BL 45 ALL

4100

0.9

2.1

BL 50-60/6

3800

1.1

3.2

BL 50-75/6

3400

1.3

3.9

BL 60 ALL

2600

1.9

5.6

BL 75 ALL

1800

2.3

7.1

8 Pole
BL 30 ALL

7000

0.5

1.1

BL 40-17/8

6500

0.7

1.4

BL 45 ALL

6000

0.9

2.1

BL 50-45/8

5500

1.1

3.2

BL 50-57/8

5000

1.1

3.9

BL 60 ALL

4500

2.1

5.6

BL 75-150/8

3000

2.3

7.1

* Relubrication intervals are based on continuous operation in ambient temperatures up to 68°F

(20° C) and should be reduced for increases in ambient temperature as follows: 77°F (25° C) x

.8, 86°F (30° C) x 0.65, 95°F (35° C) x 0.5, 104°F (40° C) x 0.4. Above 104°F (40° C) consult

our Technical Department.

Factory recommended grease for Invicta vibrators is EXXON UNIREX N2 or N3.

NOTE: The above relubrication intervals are for guidance only and may be shortened or

lengthened, if necessary, in view of actual field experience by the end user.

Table 3: Bearing Relubrication Intervals and Amounts