This water heater must be located in an area where leakage of the tank, water line
connections, or the combination temperature and pressure relief valve will not result in
damage to the area adjacent to the water heater or to lower floors of the structure.
When such locations cannot be avoided, suitable drain pan, adequately drained, must
be installed under the water heater. The drain pan must have a minimum length and
width of at least 4 in. (10.2 cm) greater than the diameter of the water heater and must
not restrict proper combustion air flow to the water heater. The drain pan, as described
above, can be purchased from your plumbing professional. The drain pan must be
piped to an adequate drain. The piping must be at least 3/4 inch (1.9 cm) in diameter
and pitched for proper drainage.

It is recommended that a minimum clearance of 4 inches (10.2 cm) be provided on the
side of the water heater for servicing and maintenance of the combination temperature
and pressure relief valve.

Minimum Clearances


This installation must allow access to the front of the water heater and adequate
clearance must be provided for servicing and operating this water heater. The water
heater may be installed on either a combustible or non-combustible floor. If the water
heater is to be installed directly on carpeting, it must be installed on top of a metal or
wood panel (or equivalent) extending beyond the full width and depth of the appliance
by at least 3 inches (7.6 cm) in any direction or, if the appliance is to be installed in an
alcove or closet, the entire floor must be covered by the panel, increase distances to
provide clearance for servicing.



DO NOT ATTEMPT TO LIGHT ANY GAS APPLIANCE IF YOU ARE
NOT CERTAIN OF THE FOLLOWING:

Liquefied petroleum gases/propane gas and natural gas have an odorant
added by the gas supplier that aids in detection of the gas.

Most people recognize this odor as a “sulfur” or “rotten egg” smell.

Other conditions, such as “odorant fade” can cause the odorant to
diminish in intensity, or “fade”, and not be as readily detectable.

If you have a diminished sense of smell, or are in any way unsure of the
presence of gas, immediately contact your gas supplier from a
neighbor’s telephone.

Gas detectors are available. Contact your gas supplier or plumbing
professional for more information.