Gas Conversion Instructions continued-

To convert from L.P. gas to natural gas
(For control shown in figure 4 only)

1) Rotate and partially depress gas control knob clockwise

to “OFF” position.

2)

Change gas regulator setting by removing cap from gas regulator. Depress and
rotate plunger clockwise

with a screwdriver releasing plunger.





Figure 4
















3) Replace

cap.

4) Remove the outer door. Remove inner door as instructed below.

a) Inner Door Removal.

i)

Disconnect resettable thermal switch wire leads (leading from
combination thermostat/gas valve).

ii) Remove (2) 1/4” hex drive screws from right side inner door.
iii) Remove (2) 1/4” drive screws from flange section of inner door.
iv) Remove (2) 1/4” drive screws from left side inner door.
v) Remove inner door and inspect per step 4b.

b) Fully inspect inner door gaskets for the following:

 Tears
 Missing

Material

 Cracks

Dirt or debris

Other imperfections that will inhibit proper seal

Gasket adhesion to inner door

Material left on combustion chamber (around opening)