Vent tables – Bradford White TW4-75S-76B-3X User Manual
Page 8
Specifications
Venting Specifications for:
48 Gallon
65 Gallon
Through the Wall
Terminating
# of
Elbows
Maximum Straight
Length ft (m)
Minimum Straight
Length ft (m)
3" Diameter (7.6 cm) PVC Vent Connector Lengths
1
55 (16.8)
2 (.6)
Through the Wall
2
50 (15.2)
2 (.6)
Through the Wall
3
45 (13.7)
2 (.6)
Through the Wall
4
40 (12.2)
2 (.6)
Through the Wall
Terminating
# of
Elbows
Maximum Straight
Length ft (m)
Minimum Straight
Length ft (m)
4" Diameter (10.2 cm) PVC Vent Connector Lengths
1
85 (25.9)
10 (3.1)
Through the Wall
2
80 (24.4)
10 (3.1)
Through the Wall
3
75 (22.9)
10 (3.1)
Through the Wall
4
70 (21.3)
10 (3.1)
Through the Roof
0
60 (18.3)
7 (2.1)
Through the Roof
1
55 (16.8)
7 (2.1)
Through the Roof
2
50 (15.2)
7 (2.1)
Through the Roof
3
45 (13.7)
7 (2.1)
Through the Roof
0
90 (27.4)
15 (4.6)
Through the Roof
1
85 (25.9)
15 (4.6)
Through the Roof
2
80 (24.4)
15 (4.6)
Through the Roof
3
75 (22.9)
15 (4.6)
Through the Wall
5
65 (19.8)
12 (3.6)
Through the Roof
4
70 (21.3)
15 (4.6)
Vent Tables
Page 8
pg_8.pdf 1
pg_8.pdf 1
3/24/06 4:58:18 PM
3/24/06 4:58:18 PM
Page 8