beautypg.com

Gas control assembly to thermal well – Bradford White TW4-75S-76B-3X User Manual

Page 27

background image

Gas Control Assembly to Thermal Well

Step 6.

Reconnect wire harnesses to gas control

per the illustration.

Step 7.

Reconnect gas piping to gas control.

Restore gas supply and check for gas

leaks.

Step 8.

To resume operation, follow the

instruction located on the lighting

instruction label or the lighting instruction

located in the installation and operation

manual.

5 pin

blower harness connection

3 pin

thermal well connection

Ground Wire

connection

Simulated Resistive

device

Igniter/sensor

connection

Thermal Well

flange slots

Gas control tabs

TTW SERVICE PROCEDURE VI

Gas Control & Thermal Well Testing

and Replacement

Page 27

24

25

Step 1.

Install threaded end of thermal well into tank. Be sure

thermal well flange is square as shown in photo 24 for

proper control alignment.

Step 2.

Route wire leads back into relief opening.

(see photo 24)

Step 3.

Align slots located on thermal well flange with tabs

located on back of gas control (see photos 24 & 25)

Step 4.

Carefully push control back onto thermal well flange

as far as possible towards water heater. Slide control

down to lock into position.

Step 5.

Install burner and connect pilot and feedline to gas

control.

Route wires

through relief

opening

pg27.pdf 1

pg27.pdf 1

3/28/06 11:49:06 AM

3/28/06 11:49:06 AM

Page 27

5 pin

blower harness connection

3 pin
thermal well connection

Ground Wire

connection

Simulated Resistive
device

Igniter/sensor

connection