beautypg.com

Remove blower to gain access to flue baffle – Bradford White TW4-75S-76B-3X User Manual

Page 33

background image

TTW SERVICE PROCEDURE XII

Flue Baffle

Inspection and replacement

Step 1.

Position gas control power switch to the “OFF” position

and unplug blower from wall outlet.

Step 2.

Disconnect vent system from exhaust adapter on top of

blower.

Step 3.

Unplug cord sets from blower. (see photo 33).

Step 4.

Remove the three blower mounting screws

(¼" nut driver) (see photo 33).

Step 5.

Remove blower with gasket from water heater.

Step 6.

Remove flue baffle from Heater (see photo 34).

Step 7.

Inspect baffle for deterioration, missing restrictors.

Clean any scale or debris build up. Replace with new

baffle as necessary.

Step 8.

Reinstall baffle into flue tube. Be sure baffle

hanger tab are inserted into notch location at the

top of the flue tube (see photos 35 & 36).

Step 9

Check Burner to insure no scale has accumulated during

this operation. See burner cleaning procedure on page 15.

Step 10. Reinstall blower on water heater. Connect vent

system and cord sets to blower. Plug water heater

into wall outlet.

Step 11. To resume operation follow the lighting instruction

located on the lighting instruction label or the lighting

instruction located in the installation and operation

manual.

Blower Mounting

Screws

Blower

Cord Sets

33

Disconnect vent

system from exhaust

adapter.

Remove blower to gain access to

flue baffle

Flue Baffle

Flue tube

notch

Baffle shown

installed in flue

tube notch.

Page 33

34

35

36

pg33.pdf 1

pg33.pdf 1

3/24/06 6:06:47 PM

3/24/06 6:06:47 PM

Page 33