beautypg.com

Bradford White M-1-TW-60T6FSX User Manual

Page 23

background image

TTW1 Universal Service

Replacement Blower

M1TW Series

Page 23

Step 7.

b.) Replace the current pressure switch
ONLY IF the model is for high altitude
(2001 ft. & above).

i. For high altitude applications, the
factory installed pressure switch
must be replaced. The correct
pressure switch is P/N
239-47192-01 with a setting of
-0.70" wc.

c.) When installing the high altitude
pressure switch, be sure to reconnect
the pressure switch tubing to both the
pressure tap and the switch itself.
Also, reconnect the wires for the
pressure switch circuit to the new
pressure switch. Ensure that
the tubing is not kinked.

Step 8.

a.) Ensure that once in place, the pressure
switch should be mounted such that its
diaphragm is in the vertical position.

Warning:

Failure to replace universal blower pressure
switch for high altitude will result in improper
water heater operation.

Disconnect (2) flag

terminals and tubing

from pressure switch

to remove.

Choose corresponding pressure switch

from kit. Verify correct P/N and setting

on label to match this model’s

requirements, as shown in Step 7b.

Be sure to reconnect

tubing and (2) flag

terminals.

Verify electrical

and tubing

connections.

Mount in vertical

position using

bracket.