beautypg.com

Bradford White M-1-TW-60T6FSX User Manual

Page 16

background image

TTW1 Universal Service

Replacement Blower

MITW -12 / -15 Series

Page 16

Step 9.

f.) Verify that all electrical connections
have been modified, as previously
indicated. Also, verify that the
pressure switch tubing is connected to
the pressure tap on the blower
and to the switch itself. Ensure that
the tubing is not kinked.

Step 10.

a.) Ensure that the pressure switch, P/N
239-47192-02, is mounted in the
vertical position, as shown. This
pressure switch comes standard in the
blower from the factory. Its vacuum
setting should read -0.80" wc.

b.) Place the access compartment cover
back on the blower and secure with (3)
screws from Step 9a. Start the lower
screw first, and when doing so, make
sure that the hole in the pressure
switch’s bracket matches up to the
hole in the blower housing.

Step 11.

Now that the universal blower is properly
modified for a -12/-15 series water heater,
the blower can be properly positioned and
secured on top of the water heater. To
place the blower on the water heater, feed
the blower from around the backside of
the water connections. Secure the
universal blower using (3) screws, P/N
239-44113-00, provided with the kit, into
the pilot holes created in Step 7. Tighten
them using a ¼” nut driver.

Verify electrical

and tubing

connections.

Mount in vertical

position using

bracket.

Secure (3)

cover

screws.

Secure (3)

blower

screws.

Warning:

Do NOT over tighten (3) screws attaching
the blower to the water heater.

This manual is related to the following products: