Route wires

through hole in

junction box.

Fasten connector

to junction box.

Step 13.

Locate new blower harness, P/N
239-47194-00, provided with the kit.
Route loose wire ends (yellow, blue,
white, and green) through knock-out
opening from Step 12c.

Step 14.

Fasten conduit connector to the junction
box.

Step 15.

Connect the wire terminals to their
corresponding locations on the
transformer:
a.) (2) Blue wires and wire terminal to the
120V-Hot post
b.) (2) White wires and wire terminal to the
120V-Common post
c.) (2) Yellow wires and wire terminal to
the 24V-Hot post
d.) (2) Green wires and wire terminal to
the 24V-Common post

Step 16.

Place the transformer all the way back
into the junction box and fasten both to
the water heater using (2) screws, P/N
239-44113-00, provided with the kit.

TTW1 Universal Service

Replacement Blower

MITW -12 / -15 Series

Page 18

Connect wire terminals from

harness to proper posts.

Fasten transformer and

junction box to jacket head

(Second screw not shown).

Warning:

Do NOT over tighten (2) screws attaching
the transformer and junction box to the
water heater.