Specifications, Wiring diagram control timings – Bradford White HE-4-50S6FSX User Manual
Page 8
Page 8
Ignition State
Timing
Pre-purge
15 seconds
Trial for Ignition
90 seconds
Flame Stabilization Period
3 seconds
Interpurge
15 seconds
Flame Failure Response Time
1.5 seconds (2 second maximum; 1 second mini-
mum)
Postpurge
15 seconds
Pressure Switch Fault Delay (failed open/close)
Retry after 2 minutes
Soft Lockout
Retry after 5 minutes
ECO Limit Lockout
Indefinite (See page 21 to reset)
Verify Resistive Delay
Retry after 2 minutes (repeats 5 times)
Simulated Resistive Load Lockout
Indefinite (cycle power to reset)
Hardware Error Lockout
Indefinite (self clears if fault clears for at least 15
seconds)