Bradford White HE-4-50S6FSX User Manual
Page 6
Page 6
in sufficient quantity to prevent normal combustion, the flammable vapor sensor recognizes this
and shuts down the pilot and main burner. Should the flammable vapors continue to burn, the
flame arrestor prevents the flames from traveling backwards and igniting vapors outside of the
combustion chamber. And, the resettable thermal switch will open and shut down the pilot and
main burner.
How to Use this Manual
It is intended for this manual to be used by qualified service personnel for the primary purpose
of troubleshooting and repair of the Bradford White Super High Efficiency atmospheric gas
water heaters. Understanding the sequence of operation section of this manual will contribute
greatly to troubleshooting the water heater.
The Honeywell WV4462 Electronic Gas Control will display error codes in the event of
abnormal operation. Error codes are listed in the troubleshooting chart beginning on page 13 of
this service manual. The troubleshooting chart will also indicate the probable cause for the error
code and direct the service professional to a service procedure to properly diagnose the
abnormal operation.
Contact the Bradford White technical support group immediately if diagnosis cannot be made
using the methods described in this service manual.
Tools Required for Service
Manometer: A liquid “U” tube type or a digital (magna-helic) type can be used. This device is
used to measure gas and/or air pressure and vacuum.
Multi-Meter: A digital type is strongly recommended. This device is used to measure electrical
values. The meter you select must have the capability to measure volts AC, volts DC, amps,
micro-amps and ohms.
Electronic Probes: In some cases, standard multi-meter probes will damage or simply not be
effective to obtain certain voltage and ohm reading. It will be necessary to have special
electronic “pin” type multi-meter probes. These probes are available at most electronic
wholesale outlets.
Thermometer: Used to measure water temperature. An accurate thermometer is recommended.
Water Pressure Gage: Used to measure water supply pressure. Also used to determine tank
pressure by adapting to the drain valve of the heater.
Various Hand Tools: Pipe wrench, channel locks, open end wrenches (3/8", 7/16", 1/2"), 12"
crescent wrench, Allen wrench set, screw drivers (common & Phillips), torx bits, 1/4" nut
driver, pliers (common & needle nose), socket set, side cutters, wire cutters, wire strippers, wire
crimpers, torpedo level, small shop vac, step ladder, flashlight, and 5 gallon pail.
How to Use this Manual
6