beautypg.com

Flammable vapor sensor testing – Bradford White HE-4-50S6FSX User Manual

Page 27

background image

Page 27

Gas Control Disassembly / Assembly (cont’d)

Step

6.

Using a slotted screwdriver (or a T-15 torx),

remove the screw (holding the cover on) at the bottom of the gas
control.

Step 7.

Depress both tabs on the top of the gas control cover and pull to remove.

Step 8.

Disconnect the temperature sensor wire harness

from the gas control board.

Flammable Vapor Sensor Testing

Step 1.

Move the gas control power switch to the “OFF”

position.

Step

2.

Disconnect the flammable vapor sensor /

resettable thermal switch (FVS/RTS) harness from the gas
control.

Flammable Vapor Sensor Testing

Gas control power

switch

FVS/RTS harness

Slotted screwdriver

Temperature sensor wire

harness