beautypg.com

Gas control assembly – Bradford White HE-4-50S6FSX User Manual

Page 26

background image

Page 26

Gas Control Disassembly / Assembly

Following the steps below allows for the removal of the gas control from the
temperature sensor well without removing the temperature sensor well from the tank.

Step 1.

Move the gas control power switch to the “OFF”

position.

Step 2.

Unplug the water heater from the wall outlet.

Step 3.

Turn off the gas supply to the water heater and disconnect the gas piping

from the gas control.

Step

4.

Disconnect the pilot tube

using a 7/16” wrench and the main burner
feedline with a 3/4” wrench from the gas
control.

Step 5.

Disconnect the wire harnesses and spark igniter/

flame sense wire from the gas control.

Gas Control Assembly

Gas control power

switch

Blower (water heater)

power cord

Pilot and main feed-

lines

Spark igniter/flame

sensor wire

Gas control

Wire harnesses

26

This manual is related to the following products: