Global parameters, Program specific parameters, 4 global parameters – B&C Technologies PF Series User Manual
Page 33: 5 program specific parameters

9.4
Global Parameters
The following parameters apply globally for the machine. They are always used no matter which
program is currently chosen.
Table 9.6: Global Parameters
Number
Description
Units
Standard value
Set value
1
Preselected program number
100
2
Empty piles on program change
0/1
1
3
Reset counter when changing program
0/1
0
4
Total counter on start page
0/1
0
5
Correction piece length after TE stop
mm
-50
6
Adjust ski width not until LE PhC XF 1
0/1
0
7
Correct piece length Photo A
0-2
0
8
Minimal piece length
mm
200
10
Duration stop stacker before flaps open
ms
350
11
Duration stacker flaps open
ms
250
12
Duration delay stacker flaps
ms
0
15
Delay push out pile
ms
500
16
Duration push out pile
ms
1000
17
Delay belt after push out
ms
0
20
Duration until jam Photocell dark
ms
3000
22
Interval pulse blowing
ms
80
23
Pulse duration
ms
40
25
Number of pieces until jam LF
3
26
Number of pieces until jam XF
4
70
Delay deploy cylinders
ms
300
80
Persist interval statistics
s
600
81
Persist interval time statistics
s
600
85
Piece length endurance run
mm
1000
86
Cycle time endurance run
ms
3500
90
Language
0-5
0
95
Duration until automatic switch-off
s
300
98
Duration until pasknife reset
s
3600
99
Current program number
0-99
0
9.5
Program Specific Parameters
The following parameters can be adjusted differently per program.
29