B&C Technologies SP Series Commercial User Manual
Page 39

STEAM INLET and CONSUMPTION:
UNITS
SP-40/45
Steam inlet size
DN
in
13
1/2
Required steam to heat bath 10F (5.55C)LOW
kg
lbs
1.2
2.4
Required steam to heat bath 10F (5.55C)HIGH
kg
lbs
1.4
3.1
Average Steam consumption per cycle
kg
lbs
23
50.6
STEAM INLET and CONSUMPTION:
UNITS
SP-60/65/75
Steam inlet size
DN
in
13
1/2
Required steam to heat bath 10F (5.55C)LOW
kg
lbs
1.5
3.2
Required steam to heat bath 10F (5.55C)HIGH
kg
lbs
1.8
4
Average Steam consumption per cycle
kg
lbs
31
66
STEAM INLET and CONSUMPTION:
UNITS
SP-100/110
Steam inlet size
DN
in
20
3/4
Required steam to heat bath 10F (5.55C)LOW
kg
lbs
2.5
5.5
Required steam to heat bath 10F (5.55C)HIGH
kg
lbs
3.4
7.4
Average Steam consumption per cycle
kg
lbs
60
132
STEAM INLET and CONSUMPTION:
Units
SP-130/135
Steam inlet size
DN
in
25
1
Required steam to heat bath 10F (5.55C)LOW
kg
lbs
3.1
6.8
Required steam to heat bath 10F (5.55C)HIGH
kg
lbs
4.4
9.6
Average Steam consumption per cycle
kg
lbs
74
163
STEAM INLET and CONSUMPTION:
Units
SP-155/165
Steam inlet size
DN
in
25
1
Required steam to heat bath 10F (5.55C)LOW
kg
lbs
3.8
8.4
Required steam to heat bath 10F (5.55C)HIGH
kg
lbs
5.8
12.76
Average Steam consumption per cycle
kg
lbs
88
194
STEAM INLET and CONSUMPTION:
Units
SP-185/195
Steam inlet size
DN
in
25
1
Required steam to heat bath 10F (5.55C)LOW
kg
lbs
5
11
Required steam to heat bath 10F (5.55C)HIGH
kg
lbs
7.7
16.9
Average Steam consumption per cycle
kg
lbs
117
194
Table 4.7: Steam Service Connection Detail