Figure 4.11: Typical Machinery Transportation Bracket Location

4.6

Drain Installation

A drain system of adequate capacity is essential to the machine performance. Ideally the water
should empty through a 4 inch vented pipe directly into a sump or floor drain. See figure 4.12 on
30.

A flexible connection must be made to a vented drain system to prevent an airlock or siphon
effect. If proper drain size is not available or practical, a surge tank is required. A surge tank in
conjunction with a sump pump should be used when gravity drainage is not possible, such as in
below-ground-level installations.

Before any deviation from specified installation procedures is attempted, the customer or installer
should contact the manufacturer. Increasing the drain hose length, installing elbows, or causing
bends will decrease drain flow rate and increase drain time, impairing machine performance. If
the drain arrangement is inadequate, the machine will not extract and will not discharge water
properly.

29