Problems controlling cellar humidity 酒窖湿度控制问题 – Wine Guardian Ducted Split Wine Cellar Cooling Systems (WGS175) - Manual User Manual
Page 87

88
Thermostat set too low on cooling
Reset thermostat to higher cooling
温控器冷却设置太低,
temperature
复位并提高温控器冷却温度
Heating coil (optional) not operating
Check for temperature rise across coil
加热线圈(可选)不工作
检查线圈温度上升
Thermostat set too low on heating
Reset thermostat to higher heating
temperature
温控器加热设置太低
提高温控器 加热设置
Thermostat not controlling temperature
Wiring integrity compromised (shorted),
replace wiring
温控器不控制温度。
接线完整性受损(短路),更换电线
Cellar Temperature is too cold (below 11°C) when unit is not running
酒窖温度过冷(低于 11 ° C)当主机未运行时
Possible Cause 可能的问题
Solution 解决方法
Too much heat loss to adjacent spaces
Increase insulation around the ductwork
Check and clean filter and coil
Coil frozen – shut off unit for two hours
过多的热量损失到相邻的空间
增加通风管道保温绝缘材料,检查和清洁
过滤网,线圈。如果线圈冷冻- 关闭主机
两个小时。
Cellar loads are too high
Install additional insulation
Replace with larger sized unit
需要制冷的酒太多
增加 道保温绝缘材料,换大号主机。
Problems Controlling Cellar Humidity 酒窖湿度控制问题
Humidity too low or supply air is too cold, without optional humidifier
湿度太低或送风太冷,无可选加湿机器
Possible Cause 可能的问题
Solution 解决方法
Not enough evaporator airflow
Remove blockage in supply or return