authorization: Masimo hemoglobin (SpHb)

This document describes how to install and activate the module. In summary, the steps are as follows:

1.

Verify that your device meets the minimum firmware requirements and, if indicated, upgrade the
firmware using the Welch Allyn Service Tool.

2.

Activate the license using the service tool and this authorization code.

AUTHORIZATION CODE

3.

Install the module by following the instructions in the service manual.

You need version 1.5.0 or later of the service tool to complete the procedures. You can download the
service tool from www.welchallyn.com/servicetool.

Check the firmware version

You must verify that the firmware version of the device is 1.70.03 or later. You can check the firmware
version on the device or through the Welch Allyn Service Tool.

To check the firmware version on the device, follow the steps below. To check the firmware version
through the service tool, go to “Start the service tool” (page 2).

To check the firmware version on the device

1.

If the device is not already on, power it on.

2.

Touch the Settings tab.

3.

Touch the Advanced tab.

Note

This authorization code activates one license on one device. The license, once activated,
is not transferable.

Note

The installation of this module must be performed by a Welch Allyn trained and
authorized technician. Installation by unauthorized personnel will void the warranty.

Mat. 719341, 80017983 Ver. A

Activate a license using the simple user interface

Before you begin, ensure that the device is powered on and connected to a computer running the
service tool, as described in “Start the service tool.”

1.

Click Add new features.

2.

Enter the authorization code and click Activate. The license upgrade activates immediately.

3.

Click Close.

4.

Power down the device.

a.

On the device, touch the Settings tab.

b.

Touch the Device tab.

c.

Touch Power down.

Install the module by following the instructions in the next section.

Install the module

Install the module and perform the functional verification tests by following the instructions in the
service manual for the device. The service manual accompanies the device or is available at
http://www.welchallyn.com.

Keep this document for your records

If the license is lost, you will need the authorization code and serial number of the device to
restore it. Record the serial number of the device below. This is your proof of purchase should the
module fail and require replacement.

Welch Allyn Technical Support

USA +1 800 535 6663

+1 315 685 4560

Japan

Latin America

+81 42 703 6084
+1 305 669 9003

Australia +61 2 9638 3000

Malaysia +603 7884 3329

Canada +1 800 561 8797

Netherlands +31 202 061 360

China +86 21 6327 9631

Singapore +65 6419 8100

European Call Center +353 46 90 67790

South Africa +27 11 777 7555

France +33 155 69 58 49

Spain +34 917 499 357

Germany +49 695 098 5132

Sweden +46 85 853 6551

Italy +39 026 968 2425

United Kingdom +44 207 365 6780

4

Welch Allyn, Inc.
4341 State Street Road
Skaneateles Falls, NY 13153-0220 USA
www.welchallyn.com

© 2012 Welch Allyn

(over)