beautypg.com

Serial interface, 1 specifications, 2 connector pin assignment – Citizen Systems iDP-3535 User Manual

Page 17

background image

iDP-3535 User’s Manual

CITIZEN

17/38

5. Serial Interface

5-1 Specifications

1) Synchronism

: Asynchronous

2) Baud rate

: 1200, 2400, 4800, 9600 BPS

(Selected by user)

3) Composition of one word

: Start bit : 1 bit
: Data bit : 7 or 8 bit

(selected by user)

: Parity bit : Odd, even or parity

(selected by user)

: Stop bit : 1 bit or more.

4) Signal polarity

: RS-232C : Mark = Logic “1”

(-3V to -12V)

: Space = Logic “0”

(+3V to +12V)

4) Receiving Control (DTR signal)

: RS-232C : Mark = Data transfer not possible
: Space = Data transfer possible

5-2 Connector Pin Assignment

Pin No.

Signal

Direction

Function

RS-232C

Name

Host / Printer

1

FG

Safety Ground

3

RD

Received Data

¡

7

SG

Signal Ground

14

FAULT

Printer ALARM Signal

¡

20

DTR

Printer BUSY Signal

¡

Notes:

1. The signal for RS-232C use are based on EIA RS-232C level.
2. Please always maintain the “Mark state”, when received data is not being transferred.
3.Compatible connector (D-Sub connector)
Printer side: Equivalent to AMPHENOL 17-13250