Tycon Power TP-SW5G(-NC) User Manual
Page 6
User’s Manual
TYCON TP-SW5G(-NC) series
TYCON POWER SYSTEMS
6
Ports 1~4 will deliver DC power over the Ethernet cable as detailed below:
* Data pair A on line 1 and 2
* Data pair B on line 3 and 6
* Data pair C plus V+ on line 4 and 5
* Data pair D plus V- on line 7 and 8
Port 5 may get DC power over the Ethernet cable, as detailed below:
* Data pair A plus V+ /V- on line 1 and 2
* Data pair B plus V-/V+ on line 3 and 6
* Data pair C plus V+/V- on line 4 and 5
* Data pair D plus V-/V+ on line 7 and 8
The terminal block on the rear panel should be wired as detailed below:
*For TP-SW5G24
Please note that the maximum power per port of 35W can only be achieved using 24VDC input operation. If
your input is 12VDC, then the total power per port should be de-rated to 17W per port.
Total output of TP-SW5G24 is 35W(802.3at) x2 or 17W (802.3af) x 4.
*For TP-SW5G
The input voltage must be in the range of 44 to 57VDC if running for 802.3af operation.
The input voltage must be in the range of 50 to 57VDC if running for 802.3at operation.
If the TP-SW5G is not powered with the above designated input voltage, it will only function as an Ethernet
switch without PoE output.