beautypg.com

Diagram a – Tjernlund CSA1 Chimney Stack Assist Kit 8504201 User Manual

Page 4

background image

3

WITH THE ECO OF THE WATER HEATER.

REQUIRED. WIRE THE LINEAR LIMIT IN SERIES

THE THERMOCOUPLE JUNCTION ADAPTER IS NOT

ON 750 MILLIVOLT (POWER PILE) HEATERS

THERMOCOUPLE JUNCTION ADAPTER

PRESSURE TAP

FROM THERMOSTAT

6' LINEAR
LIMIT LEADS

115/1/60

NAMEPLATE

MOTOR

VENTER

POWER

SWITCH

GAS PRESSURE

GAS PRESSURE SWITCH

ALUMINUM TUBING TO

24" LONG 1/4" O.D.

LINE

GAS SUPPLY

BY OTHERS

WATER HEATER

BY OTHERS

THERMOSTAT

LINE

GAS PILOT

8050013 11/30/11

CLIPS

ROUTING

CABLE

THERMOSTAT CABLE

2 WIRE JACKETED

POWER

6 FOOT

BY OTHERS

FLUE PIPE

SWITCH SET AT 185°F

SPILLAGE SENSING

LINEAR LIMIT

GAS PRESSURE

TAP PORT

NOTE:

CORD

TJERNLUND
VENT HOOD

ACTUATION AND SAFETY CONTROLS INSTALLATION

After opening carton, inspect thoroughly for hidden damage. Fan blade should rotate freely. If any damage is found notify freight carri-
er and your distributor immediately and file a concealed damage claim.

Remove the hardware packet and Safety Controls.

GAS PRESSURE SWITCH INSTALLATION

IMPORTANT: Mount gas pressure switch so that diaphragm is in a VERTICAL position, (See Diagram A).

The gas pressure switch is mounted on the casing of the water heater adjacent to the heater's thermostat/gas control valve. It should
be mounted close enough so that the supplied 1/4" tubing will reach from the gas pressure switch fitting to the thermostat/gas valve
pressure gauge port. The two provided screws are self-tapping and drilling. The screws do not require the use of a drill and their 1/2"
length assures that the inner tank will not be penetrated.

1. Adjust thermostat to “Off” and shut off gas to the water heater.

2. Mount the gas pressure switch by securing it to the heater casing with a screw in each of the two mounting holes.

IMPORTANT: Mount gas pressure switch so that diaphragm is in a VERTICAL position, (See Diagram A).

3. Install the 1/8-NPT black pipe tee to the gas pressure switch, (See Diagram A). Use thread sealant, do not over

tighten. CAUTION: Utilize the hex nut on the gas pressure switch when attaching the black pipe tee.

4. Install the supplied Brass 1/8-NPT male x ¼" compression fitting to the 1/8-NPT black pipe tee, (See Diagram A). Use thread

sealant, do not over tighten.

5. Remove the PRESSURE TAP plug from the underside of the thermostat/gas control valve and install the supplied Brass

1/8-NPT male x ¼" compression fitting, (See Diagram A). Use thread sealant, do not over tighten.
IMPORTANT: DO NOT alter the heater's PILOT GAS LINE, (See Diagram A).

6. Use plug removed in step 5 and plug new pressure tap port in tee. Use thread sealant, do not over tighten.

7. Using a tube cutter, cut the appropriate length of the supplied 1/4" tubing to reach from the gas pressure switch fitting to the

PRESSURE TAP fitting of the thermostat/gas control valve. Make sure each end of the tubing is not pinched closed.

8. Use the 1/4" tubing to connect gas pressure switch fitting to the PRESSURE TAP PORT fitting on the thermostat/gas control valve.

9. Conduct a gas leakage test of all connections as outlined in the latest edition of NFPA 54, ANSI Z223.1, part 4 or local codes.

NOTE: A "gauge pressure tap port" can be accessed by removing the 1/8-NPT pipe plug that is on the 1/8-NPT black pipe tee

(attached to the gas pressure switch).

DO NOT ALTER

GAS SUPPLY

INTO PRESSURE TAP PORT.

GAS PRESSURE SWITCH

GAS CONTROL VALVE

THERMOSTAT/

PILOT GAS LINE

8050011 11/30/11

INSTALL BRASS 1/8-NPT MALE
x 1/4" COMPRESSION FITTING

THERMOCOUPLE

BURNER GAS LINE

COMMON

MUST BE MOUNTED VERTICALLY.

GAS PRESSURE SWITCH DIAPHRAGM

IMPORTANT:

BRASS 1/8-NPT MALE x 1/4"
COMPRESSION FITTING

THERMOSTAT / GAS CONTROL

TO PRESSURE TAP FITTING OF

1/4" OUTSIDE DIAMETER

ALUMINUM TUBING - CONNECT

VALVE.

1/8-NPT BLACK PIPE TEE

1/8-NPT PIPE PLUG - NEW
PRESSURE TAP PORT

NORMALLY OPEN

MOUNTING HOLES

IMPORTANT:

A

R

HO

T

W

A

M

V

C

A

T

IO

N

GAS

VALVE

DIAGRAM A

REMOVE 1/8 NPT PRESSURE TAP