Caller id, Device type – Ring Communications RM5000EX User Manual
Page 19

March 2011 Operations Manual RM5000EX
CALLER ID
Each subscriber in the system has 12 alphanumeric characters for identification. This ID is
available for display on the called station (DAD104) and for Event Logging (DNA100). Default is all
spaces.
PROGRAMMING
The following commands are used for this feature:
SCID
Set Caller ID
LCN
List Call Number
Example: Set Caller ID for call number 14 to “Lobby”.
>SCID
cr
Call Number <10-99/*> : 14
cr
Caller ID
cr
>LCN
cr
Call Number <10-99/*> : 14
cr
Line Call In Priority Network Address Remote
Equ. Number Caller ID Type QUE Alarm Call Display Printer Video NET LEQ
==== ========= ========== ==== ==== ===== ==== ======= ======= ===== === ===
$04 14 Lobby ICM RING 1 5 ... ... ... ... ...
>
DEVICE TYPE
The device type defines the operation of intercom stations.
Type0 = Undefined
Type1 = SUB (DC shift substation)
Type2 = ICM (Master station or substation using speed-dial)
Type3 = PTT (Telephone line)
Type4 = TIE (Intersystem Tie-line)
Type5 = REM (Remote subscriber)
Type6 = ILK (Interlink)
Type7 = DAM (Direct Acces Master)
PROGRAMMING
The following commands are used for this feature.
SDT
Set Device Type
LCN
List Call Number
Page19
Ring-Master