Specifications and parts list – Reliance Controls Pro/Tran Q Series User Manual
Page 12

10
Transferring from Generator Power to Utility Power
1. Return all circuit selector switches to the LINE position.
2. Follow the procedures in the generator owner's manual to turn off the generator.
3. Unplug the power cord.
Notes on Models Without Watt Meters
If there are no watt meters for checking appliance or motor load, check the nameplate on
each appliance or motor and note the load for each.
The total running wattage for each of these models is as follows:
Model Q206
5000 watts
Models Q306, Q310
7500 watts
Models Q506, Q510
12500 watts
During an emergency situation with the generator running, the circuit selector switches
should be in the OFF or LINE position when a particular load is not needed. Failure to limit
the total load to the total running wattage may cause the generator to stall or create an
undervoltage condition that could damage an appliance motor.
Specifications and Parts List
Model
#
Q206 Q306 Q506 Q310 Q510
Max.
Watts
5000 7500 12500 7500 12500
Max. single-pole circuits
6
6
6
10
10
Max. double-pole and multi-wire
circuits
3 3 3 5 5
# of handle ties provided 1
1
1
2 2
Max. combined loads @ 125
VAC
40A 60A 100A 60A 100A
Max. combined loads
@250VAC
20A 30A 50A 30A 50A
Max. load/circuit from generator
2-30A
4-20A
2-30A
4-20A
2-30A
4-20A
2-30A
8-20A
2-30A
8-20A
Max. load/circuit from load
center
2-30A
4-20A
2-30A
4-20A
2-30A
4-20A
2-30A
8-20A
2-30A
8-20A
Power inlet, NEMA*
configuration
L14-20 L14-30 CS6375
non-NEMA
L14-30 CS6375
non-NEMA
Minimum cord gauge
AWG 12 AWG 10 AWG 6 AWG 10 AWG 6
No.
of
conductors
(wires) 4 4 4 4 4
Conduit
length
18” 18” 18” 18” 18”
Conduit, trade-size diameter
¾” ¾” ¾” 1” 1”
Optional Power Inlet Catalog #
PB20
PB30
PB50
PB30
PB50
Shipping weight (lbs) 15
15
15
23 23
Dimensions (H x W x D)
13 x 7 ¾ x 4 ½
13 x 11 ¾ x 4 ½
*National Electrical Manufacturer's Association