Automatic Phone-Out Home Monitoring

System

Freeze Alarm

Model Number: THP217

Product Description

This product is intended to monitor homes, cabins, and other premises for low temperature conditions. It is designed to

automatically call up to five telephone numbers—such as your cell phone, your cabin phone, your primary residence phone, or a

neighbor’s phone-- when the temperature drops below 42

o

F. The temperature sensor is contained within the unit

.

The control panel must be located where is has access to an active Touch Tone™ telephone line and a 120-Volt electrical outlet.

Parts List

Tools & Supplies Required to Install

Automatic Phone-Out Unit

AC/DC Wall Voltage Adapter

#2 Phillips screwdriver

6-Foot phone cord

Plastic Wall Anchors (2)

3/16” drill bit and drill

Wall Anchor Screws (2)

Telephone splitter adapter

9v alkaline battery

System Features

Installs in minutes

Audible tone played on any telephone alerts user to temperature problem

Will call up to five programmed telephone numbers when an alert condition occurs

Works on Touch Tone™ telephone lines

Does not interfere with the use of answering machines

Password-protected ON/OFF feature to disable unit when protection is not desired

Alert condition indicator light and audible signal when an alert condition is detected

Red LOW BATTERY indicator light on control panel

Operates in an ambient temperature range of 32

o

F to 104

o

F (0

o

C to 40

o

C)

FCC Approved

UL Listed wall outlet power adapter

Important Safety Information!

Read and thoroughly understand the instructions and warranty prior to installation.

Do not install the system where it would be exposed to rain, direct sunlight, or a heat source such as a radiator, heating
duct, or stove.

The built-in alarm is very loud. Never place your ear close to the unit.

Proper installation of this unit requires that the system be tested after installation to insure that the unit is compatible with
both the outgoing telephone line and the telephone(s) that will be called.

This unit is an outgoing telephone device only and will not respond to any incoming telephone calls. It is only suitable for
single line telephone systems, and is not compatible with FAX machines.

To eliminate any risk of damage, replace the battery immediately upon activation of the low battery alarm, or after any
call-out event.

Control Panel Components

Installation Instructions

1.

Remove all packaging.

2.

Remove the screw from the battery compartment cover. Install a fresh 9v alkaline battery. Carbon batteries and

rechargeable batteries are not recommended.

3.

Connect any hardwired accessory devices (sold separately) to the accessory terminal block.

4.

Locate a suitable location for the unit, preferably within six feet of both an accessible telephone jack and a 120-Volt electrical

outlet. If installing beyond six feet from the telephone jack, you will need to purchase a longer telephone cord. Use anchors if

installing into drywall or plaster. For appearance, install as level as possible

5.

Connect telephone cord from wall plate to socket marked “LINE”

6.

Connect telephone or answering machine to the socket marked “TEL”. DO NOT connect a FAX machine to this unit.

7.

Plug AC adapter into a 120-Volt electrical outlet. Insert the plug on the AC adapter into the Wall Adapter Power Socket on

the side of the control panel housing.

ALARM
OUTPUT

WALL

ADAPTER

POWER

SOCKET

LCD
SCREEN

KEYPAD

LOW

BATTERY

INDICATOR

LINE IN

TERMINAL

BLOCK

COVER

TELEPHONE

(LINE OUT)

BATTERY

COMPARTMENT

COVER

A/C

POWER

INDICATOR