1

installation manual

Keep this manual where the operator can easily find them.

Read this manual attentively before starting up the units.

For safety reason the operator must read the following

cautions carefully.

Installation must be performed in accordance with the

requirement of NEC and CEC by authorized personnel only.

1. SAFETY PRECAUTIONS

The safty precautions listed here are divided into two categories.

After completing the installation, make sure that the unit operates

properly during the start-up operation. Please instruct the customers

on how to operate the unit and keep it maintained.Also, inform

customers that they should store this installation manual along with

the owner's manual for future reference.

Be sure only trained and qualified service personnel to

install, repair or service the equipment.

Improper installation, repair, and maintenance may result in

electric shocks, short-circuit, leaks, fire or other damage to

the equipment.

If you do not follow these instrutions exactly, the unit may

cause property damage, personal injury or loss of life.

If you do not follow these instrutions exactly, the unit may

cause minor or moderate property damage, personal

injury.

CONTENTS

PAGE

SAFETY PRECAUTIONS.......................................................................................1

INSTALLATION INFORMATION........................................................................... 2

ATTACHED FITTINGS.............................................................................................3

INSPECTING AND HANDLING THE UNIT.........................................................4

INDOOR UNIT INSTALLATION.................................................................................4

OUTDOOR UNIT INSTALLATION............................................................................11

INSTALL THE CONNECTING PIPE..................................................................15

REFRIGERANT PIPE..........................................................................................16

REFRIGERANT PIPE CONNECTION ...............................................................17

CONNECTIVE DIAGRAM......................................................................................18

CONNECT THE DRAIN PIPE..............................................................................18

FRESH AIR DUCT INSTALLATION.......................................................................19

CONTROL..............................................................................................20

WIRING.................................................................................................20

TEST OPERATION................................................................................................21

Install according to this installation instructions strictly.

If installation is defective, it will cause water leakage,

electrical shock and fire.

When installing the unit in a small room, take measures

against to keep refrigerant concentration from exceeding

allowable safety limits in the event of refrigerant leakage.

Contact the place of purchase for more information.

Excessive refrigerant in a closed ambient can lead to oxygen

deficiency.

Use the attached accessories parts and specified parts

for installation.

otherwise, it will cause the set to fall, water leakage,

electrical shock and fire.

Install at a strong and firm location which is able to

withstand the set' s weight.

If the strength is not enough or installation is not properly

done, the set will drop to cause injury.

The appliance must be installed 2.3m / 7.5ft above floor.

The appliance shall not be installed in the laundry.

Before obtaining access to terminals, all supply circuits

must be disconnected.

The appliance must be positioned so that the plug is

accessible.

The enclosure of the appliance shall be marked by word,

or by symbols, with the direction of the fluid flow.

For electrical work, follow the local national wiring

standard, regulation and this installation instructions. An

independent circuit and single outlet must be used.

If electrical circuit capacity is not enough or defect in

electrical work, it will cause electrical shock or fire.

Use the specified cable and connect tightly and clamp

the cable so that no external force will be acted on the

terminal.

If connection or fixing is not perfect, it will cause heat-up or

fire at the connection.

Wiring routing must be properly arranged so that control

board cover is fixed properly.

If control board cover is not fixed perfectly, it will cause

heat-up at connection point of terminal, fire or electrical

shock.

If the supply cord is damaged, it must be replaced by the

manufacture or its service agent or a similarly qualified

person in order to avoid a hazard.

An all-pole disconnection switch having a contact

separation of at least 3mm/0.118in in all poles should be

connected in fixed wiring.

When carrying out piping connection, take care not to let

air substances go into refrigeration cycle.

Otherwise, it will cause lower capacity, abnormal high

pressure in the refrigeration cycle, explosion and injury.

Do not modify the length of the power supply cord or use

of extension cord, and do not share the single outlet with

other electrical appliances.

Otherwise, it will cause fire or electrical shock.

Carry out the specified installation work after taking into

account strong winds, typhoons or earthquakes.

Improper installation work may result in the equipment falling

and causing accidents.

WARNING

WARNING

CAUTION