OUTSIDE GLAZE-SILL INSTALLATION AND PERIMETER SEAL
SHIM UNDER SILL FLASHING
SPACE BETWEEN SILL AND FLASHING (C) TO BE
CONTINUOUSLY SEALED EXCEPT FOR 1/2"-3/4"
SPACE UNDER VERTICAL MULLIONS FOR WEEPAGE.
ONCE THE WALL IS SECURED, SEAL GROVE (D)
BETWEEN SILL FLASHING AND BACK OF SILLS.
THE QUALITY OF THE INSIDE AND OUTSIDE
PERIMETER SEALS (C AND E) MAY BE IMPROVED
BY USING FG-1192/FG-2188 RIGID PVC FILLER.
THE PART MAY BE USED IN FULL LENGTHS OR CUT
INTO PIECES. ITS PURPOSE IS TO PROVIDE
SUPPORT FOR THE BACKER ROD REGARDLESS
OF JOINT OR SIZE. PERIMETER SEAL (F) IS FOR
COSMETIC PURPOSES AND IS OPTIONAL.
E
E
E
E
FG-1122
FG-2122
FG-1000-FP-3 PART #: 7166
FG-2000-FP-3 PART #: 7944
(PARTS SOLD IN
STOCK LENGTHS.)
X 4" LONG
NOTE: 1/2"-3/4" WEEP HOLE
REQUIRED IN SEALANT AT
FLASHING (C) AT CENTER
LINE OF MULLION.
D
C
F
8
FEBRUARY 2012
F L U S H G L A Z E S E R I E S 1 0 0 0 a n d 2 0 0 0 I N S T A L L A T I O N M A N U A L