Frame-install-sill-splice-inside-glz, Sill splice, Inside glaze sill flashing installation – Oldcastle BuildingEnvelope FG-2000 User Manual
Page 19

INSIDE GLAZE SILL FLASHING INSTALLATION
SEAL WITH A NON-SKINNING,
NON-HARDENING SEALANT.
FILL BREAK IN FLASHING
AND SEAL UNDER SPLICE.
FG-2000-FP-8/9
PART #: 7965
1/4" NOM.
SEALANT
FG-2180
FG-2000-FP-2
PART #: 7165
FLASHING ANCHORS MUST
BE CAP SEALED.
FG-2000-FP-1
PART #: 7943
TWIST IN ANCHOR
SHIM UNDER SILL FLASHING
1. ANCHORS DESIGNED TO
TWIST IN.
2. SPACE ANCHORS MAX. 4" FROM
EACH SIDE OF MULLION.
3. BENT LEG ALWAYS TO
EXTERIOR.
4. STAKE ANCHORS TO PREVENT
HORIZONTAL MOVEMENT.
ANCHOR MUST FACE EXTERIOR AS SHOWN.
INTERIOR
NOTE: SILL FLASHING
SHOULD BE LEVEL AND
MAKE SURE IT IS NOT TILTED
TOWARD THE INTERIOR.
SILL SPLICE
F G - 1 0 0 0 - F G - 2 0 0 0 S T O R E F R O N T I N S T A L L A T I O N M A N U A L
Phone: 1-866-OLDCASTLE (653-2278)
Web Address: www.oldcastlebe.com
18