Frame-install-anchors-outside-glz, Outside glaze-frame installation – Oldcastle BuildingEnvelope FG-2000 User Manual
Page 8
OUTSIDE GLAZE-FRAME INSTALLATION
FG-1122
FG-2122
(PARTS SOLD IN STOCK LENGTHS.)
1. ASSEMBLY WITHOUT FLASHING
IS NOT RECOMMENDED.
2. DO NOT ANCHOR WALL THRU
VERTICAL LEG OF FLASHING.
SEALANT
ACCESS HOLE AT ALL ANCHOR LOCATIONS.
(SIZE DETERMINED BY ANCHOR.)
DRILL CLEAR HOLE IN FLASHING THROUGH
ANCHOR CLIP. THEN INJECT SEALANT INTO
HOLE IN FLASHING AND UNDER ANCHOR CLIP.
ANCHOR SIZE AND FREQUENCY SHOULD BE DETERMINED BY STRUCTURAL REQUIREMENTS.
SILL ANCHORS FG-1000-FP3/FG-2000-FP-3 AND HEAD ANCHORS FG-1122/FG-2122 SHOULD BE
LOCATED SO THAT THE ANCHOR IS NOT MORE THAN 4" FROM EACH SIDE OF THE MULLION.
FG-1000-FP-3 PART #: 7166
FG-2000-FP-3 PART #: 7944
FG-1192
FG-2188
PVC PROFILE
USED TO IMPROVE
INSTALLATION OF
BACKER ROD AND
PERIMETER SEALANT.
(OPTIONAL)
CLEAR HOLE
(SIZE DETERMINED BY ANCHOR.)
X 4" LONG
7
FEBRUARY 2012
F L U S H G L A Z E S E R I E S 1 0 0 0 a n d 2 0 0 0 I N S T A L L A T I O N M A N U A L