19_bridge_installation_ssg – Oldcastle BuildingEnvelope 6000 Series Thermal MultiPlane User Manual
Page 20

19
S E R I E S 6 0 0 0 T H E R M A L M U L T I P L A N E I N S T A L L A T I O N M A N U A L
Cap seal
fasteners
Tool sealant at mullion
and horizontal to form
a watertight seal
Keep face of bridge clear
of sealant for proper weepage
Install HP-1004 weep baffle in
bridge prior to installing face cap
Seal between
bridge & horizontal
Bed fasteners
in sealant
FS-202
(#8 x 1/2" PPH)
FG-3000-PP-53
funnel bridge
part #13664
Apply sealant to horizontal
and face of mullion prior
to installing bridge
BRIDGE INSTALLATION FOR MULTIPLANE SSG