Appendix B: Troubleshooting Your Evaluation Setup
B.3 Network Topology Overview
B.3.1 Retrieving the evaluation license:
To retrieve the evaluation license automatically, the LiveUSB host computer must have access to the Internet. The 
host computer will attempt to retrieve an IP address on its first wired interface dynamically via DHCP. Although 
wireless connections may be available on the LiveUSB host computer, they are disabled in the default configuration. 
If you wish to connect to the Internet over a wireless connection, you must determine the configuration yourself. 
B.3.2 Running the evaluation
The steps in the tutorial have been tested using wired interfaces only. Both the target and the LiveUSB host computer 
must be set to their respective static IP address. Before running the evaluation tutorial, you must switch the LiveUSB 
host computer to its static IP address. The script that sets the static IP address uses the lowest numbered eth 
interface that it finds. For example, if the host computer has eth1 and eth2 interfaces, then eth1 will be set to the 
static IP address. 
If you have trouble retrieving the license automatically, perform the following procedure to repair the problem.
Troubleshooting Your License Activation
1.
Configure your system as shown in section 2.2.
2.
From the main Fedora menu, select
 
Applications > Wind River > IP Address > Switch to DHCP. 
3.
From the main Fedora menu start the EDK agent, select 
Applications > Wind River > Embedded Development Kit Agent. 