Power supply, Atx mode / single supply mode, 11 power supply – Kontron COMe-cTH6 User Manual
Page 37
31
COMe-cTH6 User’s Guide
www.kontron.com
5.11 Power Supply
The COMe-cTH6 COM has a wide range of power inputs, from 4.75V to 20V DC. The supply voltage is applied through
the VCC_12V pins on the COM Express connector. In ATX mode the 5V standby voltage range is from 4.75V to 5.25V.
RTC power is provided on the VCC RTC pins. VCC_12V may or may not collapse in suspend states S3, S4, S5
5.11.1 ATX Mode / Single Supply Mode
ATX Mode
When an ATX power supply is connected, PWR_OK is set to low-level and VCC is off. Pressing the power button
enables the ATX PSU to turn on VCC and set PWR_OK to high-level. The ATX PSU is controlled by the PS_ON# signal,
which is generated by SUS_S3#.
State
PWRBTN#
PWR_OK
V5_StdBy
PS_ON#
VCC
S3
high
low
5V
high
0V
S5
high
low
5V
high
0V
S5 -> S0
PWRBTN Event
low -> high
5V
high -> low
0V -> VCC
S0
high
high
5V
low
VCC
Table 9: Power Supply States in ATX Mode
Single Supply Mode:
Main power (4.75V – 20V) is provided on the COM Express VCC_12V pins. Standby power, if needed, is also provided
on the VCC_12V pins. The VCC_5V_SBY pins may be floating or may be tied to a 5V source on the Carrier. RTC power is
provided on the VCC_RTC pins.
To power on the module from the S5 state, press the power button.
State
PWRBTN#
PWR_OK
V5_StdBy
VCC12V
S3
high
N/A
N/A
4.75V – 20V
S3 -> S0
high
open / high
N/A
4.75V – 20V
S5
high
N/A
N\A
4.75V – 20V
S5 -> S0
PWRBTN Event
open / high
N\A
4.75V – 20V
Table 10: Power Supply States in Single Supply Mode
NOTES: 1) Columns marked “N/A” are not applicable for the specified power mode.
2) All ground pins have to be tied to the ground plane of the carrier board.
DRAFT COPY FOR REVIEW ONLY