2 sensor thresholds, 3 field replaceable unit (fru) information, Field replaceable unit (fru) information – Kontron AM4211 User Manual
Page 51: Table 5-7 voltage sensor thresholds

36
www.kontron.com
5.1.2.2
Sensor Thresholds
Following table shows sensor thresholds for voltages
Table 5-7:Voltage sensor thresholds
5.1.3
Field Replaceable Unit (FRU) Information
This FRU information contains the IPMI defined Board and Product Information areas that hold the part
number and serial number of the board and the Multirecord Information Area that contains the PICMG
defined Module Current Requirement Record, the AMC Point-to-Point Connectivity Record and the Clock
Configuration Record.
The Internal Use Area is pre-allocated to 384 bytes and is free for customer use.
This FRU information responds to FRU ID #0, which is the ID for the MMC.
SENSOR Number / ID string
Lower Non-Re-
coverable
Lower criti-
cal
Lower non crit-
ical
Upper non
critical
Upper
critical
Upper Non-Re-
coverable
Vcc +3.3VSUS
2.802V
2.955V
-
-
3.623V
3.806V
Vcc +12V In
8.152V
9.826V
-
-
14.244V 15.918V
Vcc Vcore
0.987V
1.087V
-
-
1.165V 1.230V
Vcc +1.1V
0.971V
1.032V
-
-
1.170V 1.231V
Vcc +1.5V
1.321V
1.423V
-
-
1.579V 1.681V
Vcc +1.8V
1.062V
1.682V
-
-
1.920V
2.540V
Vcc VTT_DDR
0.643V
0.682V
-
-
0.821V
0.860V
Vcc +2.5V
2.197V
2.342V
-
-
2.660V
2.805V
Vcc +1.2V
0.907V
1.120V
-
-
1.312V
1.525V
Vcc +1.0V BCM
0.569V
0.932V
-
-
1.051V
1.414V
Vcc +3.3V
2.951V
3.093V
-
-
3.512V
3.654V
Vcc +1.2V SUS
1.053V
1.114V
-
-
1.289V
1.350V
Vcc +5V
4.126V
4.126V
-
-
5.597V
5.597V
Note:
Lower non critical and upper non critical values are not set to ensure no error in normal operation.
Note:
Vcc +1.8V Sensor is only monitored when the SyncE option is installed.