beautypg.com

2 ipmi sensors, Ipmi sensors, Table 5-1 sensor list – Kontron AM4211 User Manual

Page 44

background image

29

AM4211

www.kontron.com

5.1.2

IPMI Sensors

The MMC includes many sensors for voltage or temperature monitoring and various others for pass/fail type
signal monitoring.

Every sensor is associated with a Sensor Data Record (SDR). Sensor Data Records contain information about
the sensors identification such as sensor type, sensor name and sensor unit. SDRs also contain the
configuration of a specific sensor such as threshold/hystheresis, event generation capabilities that specifies
sensor behavior. Some field of the sensor SDR are configurable through IPMI v1.5 command and are set to
built-in initial values. The sensor also includes a field, identifying the sensor owner's address in the system.
This allows the carrier to pre-pend an appropriate code when the SDR is scanned so the reader of the sensor
list can determine which sensors belong to which physical board in the ATCA carrier or uTCA system.

From an IPMI perspective, the MMC is set up as a satellite management controller (SMC). It does support
sensor devices, and uses the IPMI static sensor population feature of IPMI v1.5. All SDRs can be queried using
Device SDR commands to the MMC.

The sensor name in its SDR has a name prefix which after module insertion is automatically adapted to the
physical position of the module in a carrier or in a μTCA chassis. The format of this prefix is:

•in AMC bay 1…8 or μTCA slot 1…8: ‘A1:’, ‘A2:’, ‘A3:’, ‘A4:’, ‘B1:’, ‘B2:’, ‘B3:’, ‘B4:’.

•in μTCA slot 9…12: 'C1:', 'C2:', 'C3:', 'C4:'.

Please note that in the case that the module is installed elsewhere, then the IPMB-L address of the module is
unknown and the interface is off.

Module sensors that have been implemented are listed in the sensor list below.

Table 5-1:Sensor list

SDR
ID

Name

Sensor Type Code

Reading Type Code

Description

Event Offset

0

IPMI Info-1

C0h
(OEM Kontron)

70h
(Discrete)

Internal Management

Controller firmware

diagnostic

1

IPMI Info-2

C0h
(OEM Kontron)

75h
(Discrete)

Internal Management

Controller firmware

diagnostic

2

FRU Agent

C5h
(OEM Kontron FRU

Info Agent State)

0Ah
(Generic Discrete)

FRU Information

Agent - FRU Data

Error Detection

Offset 6: transition to

Degraded
Offset 8: Install Error

3

ModuleHotSwap

F2h
(Module Hot

Swap)

6Fh
(Sensor Specific)

Refer to AMC.0

specification.

Offset 0: Module Handle

Closed
Offset 1: Module Handle

Opened
Offset 2: Quiesced
Offset 3: Backend Power

Failure
Offset 4: Backend Power

Shutdown
Refer to AMC.0 R2.0 Section

3.6.6 Module Hot Swap

Sensor.