4 hot swap capability – Kontron AM4211 User Manual
Page 19

4
www.kontron.com
1.4
Hot Swap Capability
The AMC supports Full Hot Swap capability as required by AMC.0 R2.0. It can be removed from or installed in
the system while it is on (without powering-down the system). Please refer to the AMC.0 R2.0 specification
for additional details.
Standards Compliance
This board is compliant to the following standards:
•
AMC.0 R2.0 Advance Mezzanine Card Base Specification
•
AMC.1 R2.0 PCI Express and Advance Switching
•
AMC.2 R1.0 Ethernet Specification
•
AMC.4 R1.0 Serial RapidIO Specification
•
MTCA.0 R1.0 Micro Telecommunication Computing Architecture Base Specification
•
IPMI v2.0.
•
RoHS compliant.
Mechanical
Characteristics
•
4HP single Mid-size AMC Module
Operating Voltages
•
Management:
3.3V +/-0.3V
•
Payload:
10VDC to 14VDC
Operation Power
•
Management:
0.495 W max., TBD W typ.
•
Payload:
40 W max., TBD W typ.
Temperature
•
Operates from -5°C to 55°C ambient air temperature with forced convection. Based on B.4.
chassis.
•
Operating @ 8 CFM:
up to 25°C
•
Operating @ 11.4 CFM:
26°C to 40°C
•
Operating @ 18.0 CFM:
41°C to 55°C
•
Non-Operating:
-40°C to 85°C
Humidity
•
Designed to meet Bellcore GR-63, Section 4.1
•
Operating:
5%-93% (non-condensing) at 40°C
•
Non-Operating:
5%-93% (non-condensing) at 40°C
Altitude
•
Designed to meet the following requirements according to Belcore GR-63, section 4.1.3:
•
Operating:
-300 m to 4,000 m (13123 ft) (GR63 4.1.3), may require additional cooling
above 1800m (5905ft)
•
Non-Operating:
-300 m to 14,000 m (45931.2 ft)
Shock & Vibration
•
Designed to meet EN 300 019 and Telcore GR-63
•
Designed to meet NEBS Level 3, Earthquake Zone 4
Safety
•
Low Voltage Directive 2006/95/EC
•
Complies with IEC/EN/CSA/ UL 60950-1
•
The board meets flammability requirement, as specified in Telcordia GR-63
•
UL 94V-0/1 with Oxygen index of 28% or greater material
Electromagnetic
Compatibility
•
Meets or exceeds the following specifications (assuming an adequate chassis):
•
EMC Directive 2004/108/EC
•
EN55022; EN55024; CISPR22; VCCI
•
EN 300 386
•
FCC 47 CFR Part 15
•
Telcordia GR-1089
Features
Description