1 sensor data record (sdr), Sensor data record (sdr) - 11, At8904m sensors - 11 – Kontron AT8901M User Manual
Page 61: At8901m software description
AT8901M
Software Description
Page 4 - 11
AT8901M User Guide
4.4.1
Sensor Data Record (SDR)
Every sensor on the Base Board is associated with a Sensor Data Record (SDR). Sensor Data
Records contain information about the sensor’s identification such as sensor type, sensor
name, sensor unit. SDR also contain the configuration of a specific sensor such as thresh-
old/hystheresis and event generation capabilities that specifies sensor behaviour. Some field
of the sensor SDR are configurable through IPMI v1.5 commands and are set to built-in initial
value. The AT8901M management controller supports sensor devices and uses the IPMI dy-
namic sensor population feature of IPMI v1.5 to merge the AMC hot swap sensor with the
AT8901M sensors population. AMC hot swap events indicated by this sensor are passed to the
ShMC. Additionally, the IPMC updates the sensor population change indicator timestamp ac-
cessible through the Get Device SDR Info command to remain compliant to IPMI v1.5.
All SDRs can be queried using Device SDR commands. Base Board sensors that have been
implemented are listed below.
Table 4-3: AT8901M sensors
IPMI Sensor Name
Unit
Scanning Enabled Under
Power State
Health LED/Sensor
IpmC Reboot
discrete
On/Off
No change
IPMI Watchdog
discrete
On/Off
No change
SEL State
discrete
On/Off
No change
IPMB0 Link State
discrete
On/Off
No change
FRU0 IPMBL State
discrete
On/Off
No change
FRU1 IPMBL State
discrete
On/Off
No change
FRU2 IPMBL State
discrete
On/Off
No change
IPMI Info-1
discrete
On/Off
No change
IPMI Info-2
discrete
On/Off
No change
FRU0 Reconfig
discrete
On/Off
No change
FRU0 FRU Agent
discrete
On/Off
No change
FRU1 FRU Agent
discrete
On/Off
No change
FRU2 FRU Agent
discrete
On/Off
No change
EventRcv ComLost
discrete
On/Off
No change
FRU0 Hot Swap
discrete
On/Off
No change
FRU1 Hot Swap
discrete
On/Off
No change
FRU2 Hot Swap
discrete
On/Off
No change
IPMC Storage Err
discrete
On/Off
No change
Temp Base Area
degrees C On/Off
Exceeds critical threshold
Icc 12v FRU0
Amps
On
Exceeds critical threshold
Vcc 12v FRU0
Volts
On
Exceeds critical threshold
Icc 12v FRU1
Amps
On
Exceeds critical threshold
Icc 12v FRU2
Amps
On
Exceeds critical threshold